SuperSigma2 AM PMS
–
V1.5.6 17-1-2020
Page 14 (97)
©2019 DMC GmbH Herten Germany
Pin 16
Contactor 2 o/p (Magnet Brake - Fan control)
This pin can have different configurations
(see “
.
In traction software only it can be connected to the negative side of the Electro Mechanical Brake Contactor coil.
The maximum rating for this connection is 3A and it is fully protected for use with inductive loads.
In both traction and pump software it can be used to drive a cooling fan when motor and/or controller temperature
sensors signal that the temperature is above a specified threshold.
•
If and electromagnetic brake is used connected to the Pin 16 the setting “
”” must be set to 0. Refer to parameter “
for further details.
Pin 17
Contactor 3 o/p (Powersteer - Fan control)
This pin
can have different configurations (see “
.
In traction software only it can be connected to the negative side of the Power Steer Contactor coil. The maximum
rating for this connection is 3A and it is fully protected for use with inductive loads.
In both traction and pump software it can be used to drive a cooling fan when motor and/or controller temperature
sensors signal that the temperature is above a specified threshold.
Pin 18
Digital o/p -- Remote LED or Brake lights or Drive OK
The function of this output is
set in “
r both traction and pump applications.
Depending on the application considered, it can be used or as a remote LED, or as a Dirve OK signal or, for traction
only, as a brake light.
Pin 19
Supply 12V -- 70mA max.
A 12V supply is available for electronic accelerator or potentiometers. The maximum supply current is 70mA.
Pin 20
CAN +12V -- 70mA max.
A 12V supply is available for external CAN isolator modules or other loads. The maximum supply current is 70mA.
Pin 21
CAN H1
CAN High communications can line to the Calibrator, Display or other Controller(s) CAN Devices.
•
The can communication lines are referred to battery ground.
Pin 22
CAN L1
CAN Low communications can line to the Calibrator, Display or other Controller(s)/CAN Devices.
•
The can communication lines are referred to the battery 0V (ground).
Pin 23
CAN 0V
Can communication lines 0V (ground) reference.
•
The can communication lines are referred to the battery 0V (ground).
Pin 24
CAN 120R Link
This pin is connected to a 120 Ohm resistor. If the controller is the CAN network wiring ending node, this pin could
be connected to the pin 25 or pin 21. See [2] for further details.