SuperSigma2 AM PMS
–
V1.5.6 17-1-2020
Page 51 (97)
©2019 DMC GmbH Herten Germany
M3-5T
I/O Pin 5 and 6
”
Sp/In/Ad
”
This sets the function of the input pins 5 and 6 on 35-way Connector.
•
If set to
0
(Speed Limit)
, then the inputs 5 and 6 can be used to limit the speed of the vehicle via the parameters
M1-22T Cutback speed 1 (I/O 5-
and
M1-33T Cutback speed 2 (I/O 5-6 set to Speed)
. The input pins are normally closed, so speed limit will be activated if input switches are opened.
•
If set to
1
(Inching)
, then the inputs 5 and 6
can be used to “inch” the vehicle.
Thus if the input 5 is activated
(input switch closed) the vehicle will move forward at speed
M1-23T Inching speed (I/O 5-6 set to Inching)
for a time defined by
. If the input 6 is
activated (input switch closed) the vehicle will move reverse at speed
M1-23T Inching speed (I/O 5-6 set to
for a time
defined by “
.
After moving forward or reverse the vehicle stops.
Input 5 and 6 will operate for inching function as normally open switches.
! IMPORTANT
For ease of adjustment, reduce the value of
before programming this parameter.
•
If set to
2 (Advanced mode)
, then the inputs 5 and 6 will be used to select three different drive styles: Normal
Drive Styles, Drive Style 1 and Drive Style 2. For each drive style it is possible to set up different ramp times for
torque and speed and different driving and braking torque level.
Inputs 5 and 6 will operate as normally closed switches input.
For the three different drive styles the following set of parameters are adopted:
i.
Normal Drive Style
(input 5 closed & input 6 closed)
:
Neutral brake ramp time “NBrkRamp”
Direction Brake torque “DBrake”
M1-11T Direction brake ramp time
Foot brake ramp time “FbrkRamp”
The maximum drive torque in Normal drive style is set to 100%.
ii.
Drive Style 1
(input 5 open & input 6 closed OR input 5 open & input 6 open)
:
Maximum Drive Torque 1 (Torque Mode Only) “MxDrTrq1”
Neutral Brake Torque 1 (Torque Mode Only) “NBrkTrq1”
M1-28T Neutral brake ramp time
Direction Brake torque 1 (Torque Mode Only) “DBrkTrq1”
Direction brake ramp time 1 “DBrkRmp1”
Foot Brake Torque 1 (Torque Mode Only) “FBrkTrq1”
Foot brake ramp time 1 “FBrkRmp1”
The maximum drive torque is adjustable by
M1-26T Maximum Drive Torque 1 (Torque Mode Only)
iii.
Drive Style 2
(input 5 closed & input 6 open):
Maximum Drive Torque 2 (Torque Mode Only) “MxDrTrq2”
Neutral Brake Torque 2 (Torque Mode Only) “NBrkTrq2”
Neutral brake ramp time 2 “NBrkRmp2”