DMEGC AC Module Installation Manual
- 9 -
Step 11:
Energize the system
Step 12:
Wiring General
Step 13:
Module Wiring
Step 14:
Array Wiring
Step 15:
Ground the DMEGC ACMs
Step 16:
Set Up and Activate Monitoring
Step 1: Operating Conditions
DMEGC Photovoltaic modules be operated within the following Operating Conditions. An installation location
with conditions outside the Operating Conditions or with other Special Conditions (see below) must be avoided.
The modules should be operated only in terrestrial applications.
The operating module temperature must be within 30
℃
(-22 F) to 85
℃
(185 F).
The wind pressure load of the installation site should be less than Load Resistance shown in Mount Locations
and Load Resistance.
Step 2: Unpacking and Handling
Do not hit the back sheet of a module with the connector when unpacking and handling.
Please do not expose the connector to rain water and/or dust .
To avoid damage to the back sheet by the connector, do not cut the string binding the cables of junction box.
Do not handle modules while holding their cables, junction box or microinverter. Handle modules while holding
the frame with both hands in any situation.