DMEGC AC Module Installation Manual
- 4 -
WARNING:
Risk of equipment damage
The Enphase Microinverter is not protected from damage due to moisture trapped in cabling systems. Never mate
microinverters to cables that have been left disconnected and exposed to wet conditions. This voids the Enphase
warranty.
NOTES:
The Enphase Microinverter has field-adjustable voltage and frequency trip points that may need to be set,
depending upon local requirements. Only an authorized installer with the permission and following requirements
of the local electrical authorities should make adjustments.
Enphase Q Cable and Accessory Safety
DANGER:
Risk of electric shock. Risk of fire.
Do not install the Enphase Q Cable terminator while power is connected.
WARNING:
Risk of electric shock. Risk of fire.
When stripping the sheath from the Q Cable, make sure the conductors are not damaged. If the exposed wires are
damaged, the system may not function properly.
Do not leave AC connectors on the Q Cable uncovered for an extended period. You must cover any unused
connector with a sealing cap.
Make sure protective sealing caps have been installed on all unused AC connectors. Unused AC connectors are
live when the system is energized.
WARNING:
Use the terminator only once. If you open the terminator following installation, the latching mechanism is
destroyed. If the latching mechanism is defective, do not use the terminator. Do not circumvent or manipulate the
latching mechanism.
When installing the Enphase Q Cable, secure any loose cable to minimize tripping hazard.
NOTES:
When looping the Enphase Q Cable, do not form loops smaller than 4.75 (12 cm) in diameter.
If you need to remove a sealing cap, you must use the Enphase disconnect tool.
When installing the Enphase Q Cable and accessories, adhere to the following
:
Do not expose the terminator cap or cable connections to directed, pressurized liquid (water jets, etc.).
Do not expose the terminator or cable to continuous immersion.