― 72 ―
― 71 ―
DC current
Range
Accuracy
Input resistance**
600.0
μ
A
± (0.2 % rdg + 4 dgt)
$SSUR[
6000
μ
A
60.00 mA
$SSUR[
600.0 mA
6.000 A
$SSUR[
10.00 A*
* > 6 A: Cool down more than 3 minutes after measuring 1 minute.
< 6 A Continuable
**Fusing resistor not included
AC current ACA and DC+AC current DC+AC A
Range
Accuracy
Input resistance**
50 Hz
〜
60 Hz
600.0
μ
A
± (0.6 % rdg +3 dgt)
$SSUR[
6000
μ
A
60.00 mA
$SSUR[
600.0 mA
± (1.0 % rdg +3 dgt)
6.000 A
10.00 A*
± (0.8 % rdg +6 dgt)
$SSUR[
40 Hz
〜
1 kHz (Except 50 Hz
〜
60 Hz)
600.0
μ
A
6000
μ
A
± (0.8 % rdg +4 dgt)
$SSUR[
60.00 mA
$SSUR[
600.0 mA
± (1.0 % rdg +4 dgt)
6.000 A
10.00 A*
± (0.8 % rdg +6 dgt)
$SSUR[
* > 6 A: Cool down more than 3 minutes after measuring 1 minute.
< 6 A Continuable
**Fusing resistor not included
5HVLVWDQFH
Range
Accuracy
N
NN
± (0.1 % rdg + 3 dgt)
0
± (0.4 % rdg + 3 dgt)
0
± (1.5 % rdg + 5 dgt)
99.99 nS
± (0.8 % rdg+10 dgt)
2SHQFLUFXLWYROWDJH9GF9GFIRU0UDQJH
)RU$XWR
・
V function
(
Resistance)
Range
Accuracy
N
NN
± (0.5 % rdg+4 dgt)
0
± (0.8 % rdg+3 dgt)
0
± (2.0 % rdg+5 dgt)
Temperature coefficient:
0.5 x (accuracy @23±5
℃
)/
℃
@(0
℃
to 18
℃
or 28
℃
to 40
℃
)
2SHQFLUFXLWYROWDJH9GF9GFIRU0UDQJH
Temp (
℃
&
o
F)**
Range
Accuracy*
-50
℃
〜
1000
℃
± (0.3 % rdg + 2 dgt)
-58
o
F
〜
1832
o
F
± (0.3 % rdg + 5 dgt)
* Accuracy with K-type thermocouple K-type thermocouple
range and accuracy not included
**Cool down more than 30 minutes after measuring DCA or
ACA.