― 74 ―
― 73 ―
Frequency (Hz)
Measuring ranges
Input sensitivity*
Frequency ranges
60.00 mV
40 mV
15.00 Hz to 50.00 kHz
600.0 mV
60 mV
9.999 V
2.5 V
15.00 Hz to 10.00 kHz
99.99 V
25 V
999.9 V
100 V
600.0
μ
A
60
μ
A
15.00 Hz to 3.000 kHz
6000
μ
A
600
μ
A
60.00 mA
40 mA
600.0 mA
60 mA
6.000 A
4 A
10.00 A
7 A
Accuracy: ±(0.04 % rdg + 4 dgt)
*Specified based on sine wave RMS
Logic level frequency (
) and Duty cycle (D%)
DCmV function
Range
Accuracy*
Frequency
5.000 Hz to
1.000 MHz
± (0.03 %rdg+4 dgt)
Duty cycle
0.00 % to
100.0 %
± (3 dgt/kHz+2 dgt) **
* Sensitivity: 2.5 Vp (Square wave) for 3 V and 5 V logic family
** Frequency range: 5 Hz to 10 kHz
Capacitance
Range
Accuracy*
60.00 nF, 600.0 nF***
±
(
0.8 % rdg + 3 dgt
)
6.000
μ
F
±
(
1.0 % rdg + 3 dgt
)
60.00
μ
F
±
(
2.0 % rdg + 3 dgt
)
600.0
μ
F **
±
(
3.5 % rdg + 5 dgt
)
6.000 mF **
±
(
5.0 % rdg + 5 dgt
)
25.00 mF **
±
(
6.5 % rdg + 5 dgt
)
* Accuracies with film capacitor or better
** In manual-ranging mode, measurements not specified below
50.0
μ
F, 0.54 mF and 5.4 mF for 600.0
μ
F, 6.000 mF and 25.00 mF
ranges respectively
*** In manual-ranging mode, the accuracy for measurements
below 5.4 nF for 60.00 nF range and 54 nF for 600.0 nF range is:
±(0.8 % rdg + 6 dgt)
Diode test
Range
Accuracy
Test current
Open circuit
voltage
2.000 V ± (1 % rdg +1 dgt)
Approx. 0.4 mA
< 3.5 V
Continuity check
7KUHVKROGOHYHOWR
Response time: < 100
μ
s