PERIM            ALL

DISARM?

or

POWER

ENTRY DELAY
All Systems

 - Once the protected door is opened and the entry

delay starts, the keypad displays 

ENTER CODE: -

. Present your

card to the reader.  Once it is validated, the system disarms all
areas accessible by you and activates the Door Strike relay.
Area systems provide a delay to allow selected areas only to be
disarmed. See Arming and Disarming above.

The system arms or
disarms the areas
and activates the
Door Strike relay.

All/Perimeter system Arming and Disarming 

- Press COMMAND. The keypad

displays 

PERIM  ALL

 (when arming) or 

DISARM?

. Press the Select key under

the desired option. The keypad displays 

ENTER CODE: -

. Present your card

to the reader. Once it is validated by the system, both

 

areas arm or disarm

automatically and the Door Strike relay activates.

Home/Away system Arming and Disarming 

- Present your card to the reader. If the system is armed, once the

card is validated all areas are disarmed

.

If the system is disarmed when you present your card, once it is validated all areas are armed in the AWAY mode.

POWER

    ABC SECURITY

ENTER CODE: -

Access door is

opened.

POWER

The system disarms the areas and activates
the Door Strike relay.

Using the access reader for user menu access

You can also use a card reader to access the User Menu.  When the 

MENU?  NO YES

 display is shown,. present your

proximity card to the reader.

Compatible Access Devices

The 791 and 793 Keypads are compatible with the following readers and access keypads.

I N T R U S I O N   •   F I R E   •   A C C E S S   •   N E T W O R K S

2 5 0 0   N o r t h   P a r t n e r s h i p   B o u l e v a r d

8 0 0 - 6 4 1 - 4 2 8 2

w w w . d m p . c o m

M a d e   i n   t h e   U S A

S p r i n g f i e l d ,   M i s s o u r i   6 5 8 0 3 - 8 8 7 7

LT-0291 (8/02) © 2002 Digital Monitoring Products, Inc.

Specifications

Operating Voltage

8.5 - 16 VDC

Current while in Standby:

100mA + 1.6 per
active zone

Current while in Alarm:

100mA + 2 per
zone in alarm

Current with Door Relay On: 130mA
Dimensions

6.5” W x 5” H x 1” D

Panel Compatibility

DMP XRSuper6, XR20, XR40, XR200, XR200-485, and XR2400F

Command Processor™ Panels

Approvals

• Underwriters Laboratories
• New York Material Equipment Acceptance (MEA)
• California State Fire Marshal (CSFM)
• Factory Mutual (FM)

Readers and Access Keypads

Current while in Standby

Current while Reading

PP-6005B ProxPoint Plus

30mA

75mA

MP-5365 MiniProx

20mA

110mA

PR-5455 ProxPro II

25mA

125mA

TL-5395 ThinLine II

20mA

115mA

MX-5375 Maxi-Prox

200mA

700mA

VP-6100 V-Prox

150mA

250mA

VP-6200 V-Pass

200mA

250mA

SSWiLW Keypad

6.2mA

38mA

SSWFX Keypad

15mA

15mA

SSWiLM-AL Keypad

19mA

49mA

SS/WG-Q15 Keypad

1.6mA

47.7mA

Summary of Contents for 791 Easy Entry

Page 1: ...the gauge of wire This distance can be in the form of one long wire run or multiple branches with all wiring totaling no more than 2 500 feet 3 Maximum number of devices per 2 500 feet circuit is 40 Note Each panel allows a specific number of supervised keypads Additional keypads can be added in the unsupervised mode Refer to the panel s installation guide for the specific number of supervised key...

Page 2: ...r magnetic lock Door Contact Zone with Soft Shunt If the door being released by the keypad is protected you can provide a 40 second shunt by connecting its contact to zone 2 White Red pair on the keypad and enabling the Soft Shunt feature See ACTIVATE ZONE 2 SHUNT on page 4 and Door Strike Relay Operation on page 5 Once the door strike relay is activated the user has 5 seconds to open the door con...

Page 3: ...tions Menu The Easy Entry keypads also contain a Keypad Options and Keypad Diagnostic program that allows installers and service technicians to configure and test the keypad operation You can only access the Installer Options Menu through the User Options function After holding down the Back Arrow and COMMAND keys for a few seconds and getting the SET BRIGHTNESS display enter the code 3577 INST an...

Page 4: ...Soft Shunt for door contacts Zone 2 must be programmed into the panel ACTIVATE ZONE 3 EXIT NO YES Select YES to enable the Request to Exit feature on zone 3 Zone 3 is included in panel programming by default 4 DIGIT ENTRY CARDS NO YES Select YES to enable the 4 Digit Entry Cards function on Home Away or other systems that require 4 digit user codes ALL NO YES DELAY 2 Select the number of seconds t...

Page 5: ...oor Strike relay activates for five seconds Note The length of the 5 second delay is programmable when the keypad is used on an XR200 485 During this time the access door connected to zone 2 must be opened to start the 40 second entry exit timer and zone soft shunt See the timeline shown below 1 5 5 Second Strike Access door is opened 40 Second Soft Shunt and entry exit timer 40 Seconds At 30 seco...

Page 6: ...s the Door Strike relay Using the access reader for user menu access You can also use a card reader to access the User Menu When the MENU NO YES display is shown present your proximity card to the reader Compatible Access Devices The 791 and 793 Keypads are compatible with the following readers and access keypads I N T R U S I O N F I R E A C C E S S N E T W O R K S 2500 North Partnership Boulevar...