10
LCD Keypad Installation Guide
aLL?:
nO yeS
deLay:
2
Arming/Disarming Wait Time
(7563/7563A,
7573/7573A only)
Select the number of seconds (1-9) the keypad should wait
when an area system displays ALL? NO YES during arming/
disarming or a HOME/SLEEP/AWAY system waits during
arming only. If NO or YES, or HOME, SLEEP, or AWAY is not
manually selected before the delay expires, the keypad
automatically selects the YES or the AWAY key. Select zero
(0) to disable this feature. The delay also occurs when any
credential is presented for arming the Home/Sleep/Away
system.
Card OptiOnS
dMp
CUStOM
Card Options
(7563/7563A, 7573/7573A only)
Select DMP to indicate the reader sends a 26-bit DMP data
string. To save the DMP option, press the left top row Select
key under DMP. Default is DMP.
Select CUSTOM if using a non-DMP credential. To select
CUSTOM press the right top row Select key.
Custom Card Definitions
Wiegand COde
Length:
26
Wiegand Code Length
(7563/7563A, 7573/7573A only)
When using a custom credential, enter the total number of
bits to be received in Wiegand code including parity bits.
Press any top row Select key to enter a number between
0-255 to equal the number of bits. Default is 26 bits.
Typically, an access card contains data bits for a site
code, a user code, and start/stop/parity bits. The starting
position location and code length must be determined and
programmed into the keypad.
0 1 1 1 0 1 0 1 1 0 1 1 0 1 0 1 0 0 0 1 1 0 0 1 1 1
First Bit
Received
Position = 0
Site Code
Position = 1
Length = 8
User Code
Position = 9
Length = 16
Last Bit
Received
Position = 25
In this example the HID Wiegand Code Length = 26 bits.
Figure 8: Data Stream Bit Location Example