background image

Thinline Icon Series User’s Guide

Alert Operation

Steady Tone

 

A trouble condition on the system.  A zone    

 

number may be displayed.  Pressing any key    

 

silences the steady alert tone.

1 One-Second Beep 

Indicates the successful completion of a function. 

4 Short Beeps

 

When an incorrect key or function is entered.

1 Short Beep

 

Each time a key is pressed.

Panic Key Operation

Your keypad may be programmed to send a Panic, Emergency, or Fire 

report to your monitoring station.  If this option is programmed for your 

keypad, icons appear below the top row Select keys.  Press and hold the 

two Select keys adjacent to the desired icon for 2 seconds and a beep 

from the keypad is heard.  The report is sent to your monitoring station.

 

Top Row Select Keys

Police

Emergency

Fire

Extending the Schedule

  Your system may be programmed with a schedule to    

 

identify authorized disarmed periods.  This option displays  

 

and a steady tone sounds when the authorized disarmed  

 

period is about to expire.  Press the Select key under    

 

EXTEND and enter your user code to extend the schedule  

 

for an additional hour.  If more than one hour is needed,  

 

after entering a user code, press the number of hours  

 

between one (1) and the maximum nine (9).

System Functions

Door Chime 

You can enable monitor for all Perimeter zones in the system to sound a 

doorbell chime at the keypad anytime a zone is opened.  Press and hold 

the CHIME (5) key for two seconds.  The Door icon will display and the 

doorbell chime sounds.  Pressing the CHIME key again for two seconds 

turns off this function.

Easy Exit 

This function allows you to exit your home while the system is armed.  

Press and hold the EXIT (8) key until the exit countdown begins to 

display and then exit.  The system automatically arms again after the 

countdown completes.

Outputs On/Off 

+[your code]+[output number]

Your system may have lights or other devices connected to outputs that 

you can turn on or off using the keypad.  Press and hold the OUTPUT 

(0) key until the keypad beeps.  Enter your user code and then the two-

digit number of the output including any leading zero such as 01.  This 

changes the output from off to on or vise versa.

Arming the System

Arming with a Code or Proximity Credential

While the Thumbs Up icon is displaying, enter your user code or 

present a proximity credential to begin the exit countdown.  Arming is 

delayed until the end of the countdown.  Pressing the INST key during 

the exit countdown immediately arms the system and removes all 

entry/exit delays.  An alarm would immediately occur should an exit 

door be opened.

Arming with Shortcut Keys 

While the Thumbs Up icon is displaying, press and hold the ALL, HOME, 

PERIM or SLEEP key for two seconds to arm your system.

 

ALL arms the entire system.

 

HOME or PERIM arms the Perimeter zones leaving the

 

Interior disarmed.

 

SLEEP arms the Perimeter and Interior zones leaving the  

 

sleeping area disarmed. (optional)

 Arming with Faulted Zones (Thumbs Down)

Thumbs down displays and the keypad sounds four short 

beeps when a burglary zone is faulted while arming the 

system. The zone number is shown in the 3-character 

display.  If the problem is simply an open door or window, 

press the Back Arrow key, correct the problem, and 

try arming again. If the problem cannot be corrected, 

press the Select Key under BYPASS to go ahead and arm 

the system.  A zone remains bypassed until the system 

is disarmed.  If no selection is made, the system will 

automatically force arm any faulted burglary zones without 

bypassing.

Disarming the System

Disarming with a Code or Proximity Credential

When the Armed (Lock) icon is displaying, enter your user code or 

present a proximity credential to disarm the entire system.

Disarming During an Alarm

Enter your user code or present a proximity credential to silence the 

siren leaving the system armed.     
After a user code is entered to silence the siren, CANCEL/VERIFY 

displays allowing you time to investigate a burglary alarm prior to 

disarming the system. 

  If a valid alarm has 

not

 

occurred, choosing CANCEL    

 

disarms the system and sends a Cancel or Abort message  

 

to the Central Station. 

  If the alarm is valid, choosing VERIFY sends a Verify    

 

message to the Central Station.  The system remains    

 

armed to provide continued intrusion detection.

The Icons

  AC Power 

 

On Steady - AC power is good.

 

Pulsing - AC power is off.

  Battery

 

On Steady - Battery power is good.

 

Pulsing - Battery power is low.

  Armed Status

 

Open Lock - The system is completely disarmed.

 

Closed Lock -  Some or all areas are armed.  See System  

 

Displays A, H, P or S.

 

Closed Lock/Instant - Some or all areas armed Instant.  See  

 

Arming the System.

 

Door Chime

 

Door or window perimeter zone(s) are selected for monitor.   

 

See Door Chime.

 

Thumbs Up

 

All burglary protection zones are normal and system is    

 

ready to arm.

 

Thumbs Down

 

System is not ready to arm due to a burglary zone in a    

 

faulted state such as an open door.  See Zone Status.

  Telephone Handset

 

Pulsing - A system message being sent to your monitoring  

 

station failed to transmit over the telephone line.

  Network Connection

 

On Steady - Your system is programmed for Network  

 

 

(Internet) communication and is functioning properly.

 

Pulsing - Network (Internet) communication is interrupted.

 

Burglar

 

A burglary alarm has occurred.  The zone number is shown in  

 

the 3-character display.

 

Flame

 

A fire alarm has occurred.  The zone number is shown in  

 

the 3-character display.

Reviews: