Digital Monitoring Products
XR150/XR550 Series Canadian Installation Guide
6
INTRODUCTION
3.3
Accessory Devices (continued)
DMP Two-Way Wireless Devices (continued)
1142BC Two-button Hold-up Belt
Clip Transmitter
Provides two-button hold-up operation with a belt clip.
1142 Two-button Hold-up
Transmitter
Provides permanently mounted under-the-counter two-button hold-up operation.
1145-4 (Four-Button)
1145-2 (Two-Button)
1145-1 (One-Button)
Key Fob transmitters designed to clip onto a key ring or lanyard.
1164 Wireless Synchronized
Smoke Detector
Commercial or residential, battery powered, wireless, low profile, photoelectric smoke
detector, with synchronizing sounder.
1166 Wireless Smoke Ring
Installs on any traditional AC-powered, three wire, interconnected smoke alarm system.
1183-135R Heat Detector
Fixed temperature and rate-of-rise heat detector.
1184 Carbon Monoxide Detector
Carbon Monoxide Detector.
Interface Modules
736P Radionics™ Popit Interface
Allows a Radionics™ POPIT System to interface with DMP XR150/XR550 Series panels while
maintaining Radionics™ wiring.
738A Ademco Interface
Allows Ademco™ 5881 wireless receivers to interface with DMP XR150/XR550 Series panels.
738I ITI Interface Module
Allows ITI™ SuperBus™ 2000 Series wireless receivers to interface with DMP XR150/XR550
Series panels.
738Zplus Z-Wave Interface
Module
Provides connection for Z-Wave modules.
Indicating and Initiating Devices
860 Relay Output Module
Provides one relay and three relay sockets for expansion of up to four relays.
865 Supervised Style W or X
Notification Circuit Module
Provides supervised alarm current when using the XR150/XR550 Series panel bell output
and up to 5 Amps at 12 or 24VDC when using a listed auxiliary power supply. The 865
can supervise 2-wire or 4-wire style circuits for opens and shorts with individual LED
annunciation.
866 Style W Notification Circuit
Module
Provides supervised alarm current using the XR150/XR550 Series panel bell output and up
to 5 Amps at 12 or 24VDC when using a listed auxiliary power supply. The 866 can supervise
2-wire Style W circuits for opens and shorts.
867 Style W LX-Bus Notification
Circuit Module
Provides supervised alarm current using the XR150/XR550 Series panel bell output and up to
5 Amps at 12 or 24VDC when using a listed auxiliary power supply. The 867 connects to the
XR150/XR550 Series panel LX-Bus™ and provides one 2-wire Style W notification circuit for
open and short conditions. Individual Bell Relay addresses Bell Ring styles.
869 Dual Class A Style D
Initiating Module
Provides two Class A, Style D, 4-wire initiating zones for connecting waterflow switches and
other non-powered fire and burglary devices.
Keypads
LCD keypads
Allows you to control the panel from various remote locations. Connect up to sixteen
supervised Model 630F Remote Fire Command Center, 7060, 7063, 7070, 7073, 7160, 7163,
7170, 7173 Thinline™ keypads, 7060A, 7063A, 7070A, 7073A Aqualite™ keypads, and 7872 and
7873 Graphic Touchscreen keypads to the keypad bus using terminals 7, 8, 9, and 10.
9000 Series Wireless Keypads
Allows you to control the panel from various remote locations. Connect up to seven
9060/9063 Wireless Keypads.
9800 Series Wireless Graphic
Touchscreen keypads
Allows you to control the panel from various remote locations. Connect up to seven 9862
Wireless Keypads.
Addressable Smoke Detectors
521LX, 521LXT
Single-zone, addressable conventional smoke, smoke/heat detectors that connect to the
LX-Bus. Includes remote maintenance reporting, drift compensation, and multi-criteria
detection.
2W-BLX, 2WT-BLX
Single-zone, addressable conventional smoke, smoke/heat detectors that connect to the
LX-Bus. Includes drift compensation.