XR150/XR550 Series Canadian Installation Guide
Digital Monitoring Products
1
INTRODUCTION
Product Specifications
1.1
Power Supply
Transformer Input:
Model 327CAN, plug-in — Primary input: 120 Vac, 60 Hz, Secondary output: 16.5 Vac 50 VA
Model FTA7516 ATC Frost from Standex Electronics — Primary input: 120 Vac, 60 Hz,
Secondary output: 16 Vac 75 VA
Standby Battery:
12 VDC, 1.0 Amps Max. charging current
Models 365, 366, 368, or 369
Replace every 3 to 5 years
Auxiliary:
12 VDC output at 1.0 Amp Max using Model 327CAN
Bell Output:
12 VDC at 1.0 Amp Max using Model 327CAN
Auxiliary:
12 VDC output at 1.5 Amp Max using Model FTA7516
Bell Output:
12 VDC at 1.5 Amp Max using Model FTA7516
All circuits are inherent Power Limited except the red battery wire and AC terminal.
1.2 Communication
• Built-in network communication to DMP Model SCS-1R Receivers (Panels with Network/Encryption only)
• Built-in 128-bit or 256-bit encrypted communication to DMP Model SCS-1R Receivers (XR550E only)
• Built-in Contact ID communication to DMP Model SCS-1R Receivers
• Optional 893A Dual Phone Line Module with phone line supervision
• Can operate as a local panel
Note:
256-bit encrypted messages to SCS-1R receiver only communicate when using SCS-104 Receiver Line
Cards with Version 102 or higher software.
1.3
Panel Zones
Eight 1k Ohm EOL burglary zones (zones 1 to 8)
Two 3.3k Ohm EOL powered zone with reset (zones 9 and 10)
1.4
Keypad Bus
You can connect up to a total of 16 of the following supervised keypads and expansion modules to the keypad bus:
• Alphanumeric keypads
• Single-zone detectors
• Access control modules
• Wireless Keypads (maximum of 7)
• Four- and/or single-zone expansion modules
1.5 LX-Bus™
You can connect the following devices to the LX-Bus™ connections provided on the panel. See Accessory Devices
section 3.3.
• Four, eight, sixteen- and/or single-zone expansion modules
• Single-zone detectors
• Relay output expansion modules
• Graphic annunciator modules
1.6 Outputs
The XR150/XR550 Series provides two Single Pole, Double Throw (SPDT) relay outputs which require the installation
of two Model 305 relays, each rated 1 Amp at 30 VDC resistive (power limited sources only). A Model 431 Output
Harness is required to use these outputs.
The panels also provide four open collector outputs rated for 50mA each. The open collector outputs provide ground
connection for a positive voltage source. A Model 300 Output Harness is required to use these outputs.