Digital Monitoring Products
XR150/XR550 Series Canadian Installation Guide
4
INTRODUCTION
System Components
3.1
Wiring Diagram
The XR550 Series diagram below shows some of the accessory modules you can connect for use in various
applications. A brief description of each module follows in section 3.3.
AC
1
2
3
4
5
6
7
8
10
11 12 13 14
15 16
17
18 19
9
20
21 22
23
24 25 26 27 28
+B
BELL GND
SMK GND
RED YEL GRN BLK
Z1
Z2 Z3
Z4 Z5
Z6 Z7
Z8 Z9+ Z9– Z10+ Z10–
AC
–B
GND
GND
GND
GND
1k Ohm 1k Ohm 1k Ohm
DISARM
ARM
Auxiliary/Smoke Power
Total current combined from
terminals 7, 11, 25, 27, XBUS
and LX500-LX900
1.5 Amp Max
13.8 VDC to 10.2 VDC
s
s s
s
s
LX
800
LX
900
J4
Tamper
K6
K7
Output 1
Output 2
J3
Phone Line
Battery
Start
J8
J16
Reset
Out1
Out2
Outputs 3-6
J11
3
4
5
6
J2
OVC
XR550 Series
Canadian Panel
LX
500
LX
700
XBUS
J13
J14
J9
J15
J19
J17
J24
Form C Relays (J2)
Output Color Code–Model 431 Harness
Output 2 N/O Orange/White
Output 2 Com White/Gray
Output 2 N/C Violet/White
Output 1 N/O Orange
Output 1 Com Gray
Output 1 N/C Violet
Annunciator Outputs (J11)
Output Color Code
Output 3
Red
Output 4
Yellow
Output 5
Green
Output 6
Black
s
s
J12
75VA
50VA
Listed Resistors
1.0k Ohm - DMP Model 311
3.3k Ohm - DMP Model 309
10K Ohm - DMP Model 308
Smoke
Detector
3.3k Ohm 3.3k Ohm 3.3k Ohm 3.3k Ohm
1k Ohm
Front
Tamper
Rear
Tamper
16 to 18 gauge wire
Maximum AC Wire distance
with 16 gauge wire: 70 feet
with 18 gauge wire: 40 feet
RED
BLACK
Cold Water
Pipe Earth
Ground
Bell
Zone
1
Zone
2
Zone
3
Zone
4
Zone
5
Zone
6
Zone
7
Zone
8
3.3k Ohm
Resistor DMP
Model 309
3.3k Ohm
Resistor DMP
Model 309
Zone Expander
Model 715
7mA @ 12 VDC
Models 715-8, 715-16
20mA @ 12 VDC
Use Listed Power Supervision
Relay rated at 12 VDC.
1k Ohm
s
= Supervised Circuit
Zone
9
Zone
10
22
gauge
mi
ni
mum
22
gauge
mi
ni
mum
22
gauge
mi
ni
mum
22
gauge
mi
ni
mum
RED
YELL
O
W
GREEN
BL
ACK
1k Ohm 1k Ohm 1k Ohm
Zone Expander
Model 714
7mA @ 12 VDC
Models 714-8, 714-16
20mA @ 12 VDC
RED
YELLOW
GREEN
BLACK
RED
s
The plug-in transformer
shall plug into a 120 VAC
60 Hz outlet not
controlled by a switch.
1k
Ohm
1k
Ohm
1k
Ohm
1k
Ohm
1k
Ohm
1k
Ohm
1k
Ohm
1k
Ohm
1k Ohm
Zone Expander
(up to 8 zones)
Model 712-8
19mA @ 12
VDC
Zone
Expander
Model 711
7mA @ 12
VDC
1k
Ohm
Keyswitch Arming
can be connected
to any zone.
Earth Ground
s s s
s
s
s
s
s s
s s
s s
s s
s
s
s
s
s
s
s
s
s
s
s
s
s s s s
s s s s
s
s s s
s s s s
s
s
s
s
s
s
s
s
s
s
s
¼"
AC Wiring must be in conduit and exit
out the left side of the enclosure.
Wiring on terminals 5 through 22 must
exit right and maintain 1/4" separation
from the AC and battery positive wiring.
CAUTION:
DO NOT USE LOOPED WIRE
UNDER TERMINALS. BREAK WIRE RUN TO
PROVIDE SUPERVISION OF CONNECTIONS.
Heat detectors, pull
stations, or any other
contact devices listed
for Fire Protective
Signaling can be
connected to zones
9 and 10.
Zones 9 and 10 and
Model 715 compatibility
identifier: A
Maximum operating
range: 13.8 VDC to
9.7 VDC.
Class B (Style A).
WARNING: Incorrect
connections may cause
damage to the unit.
Front and Rear
tamper protection
included with
Model 350A
Attack Resistant
Enclosure.
Bell cutoff time
range is 5 to 99
minutes, non-coded.
Bell
12 VDC
Minimum cutoff time 15 min.
1.5 Amp Max using FTA7516
Figure 1: XR550 Canadian Wiring Diagram
3.2
Lightning Protection
Metal Oxide Varistors and Transient Voltage Suppressors help protect against voltage surges on XR150/XR550 Series
input and output circuits. Additional surge protection is available by installing the DMP 370, 370RJ Lightning
Suppressors or Model 270 Network Transient Suppression Module.