background image

PIDC0F0: MONOSTABLE TIME

Setting the monostable pulse duration

The relays used in the 5202R-EP work in bistable mode; that
is: when (and as long as) triggered, they remein in active
state.
the function cen be reverted to monostable mode (pulse con-
tact mode), and the contact closure time can be set using the
function C0F0.

Parameter: <Slot number> <Monotime>

where: 

Slot number = 0001: Slot no. 1
Slot number = 0002: Slot no. 2
Slot number = FFFF: all

   Monotime: $01...$7F (25ms steps)

         $FF: bistable Mode

Press GET to display the current setting.
Example: both outputs are set to bistable
mode (default)

To set output 2 to monostable mode using
a pulse dauration of 0.4 sec (400msec),
enter:

0002 10   (hex)

10hex = 16dez, 16*25ms = 400ms

Press SET to write data.

Verify:

Press GET to read current data.

Relay 2 will now operate in monostable
mode using a pulse duration of 0.4 sec.

Summary of Contents for SOUNDLIGHT 5202R-EP

Page 1: ...BE ACCURATE HOWEVER SOUNDLIGHT DOES NOT ASSUME ANY RESPONSIBI LITY FOR ERRORS OR OMISSIONS THE USER HAS TO CHECK THE SUITABILITY OF THE EQUIP MENT FOR THE INTENDED USE SOUNDLIGHT EXPRESSLY EXCLUDES AN...

Page 2: ...age 115 230VAC signal loss In the case of a loss of the drive signal a pre definable action will be taken cost effective The SOUNDLIGHT 5202R EP is a cost effective solution for many purposes General...

Page 3: ...alike Cage Clamp Connectors The decoder SWINGC4 consists of 6 terminal blocks Termin als are based on screwless WAGO cage clamp technology which prevents loose connections and guarantees safe elect ri...

Page 4: ...uitable electrical cabinet or housing The operating conditions see chapter Technical Da ta must be met at all times Connectors The DMX relay 5202R EP consists of 6 inputs and outputs CN1 DMX IN OUT Ri...

Page 5: ...al OK A valid DMX signal is being received rot ERROR Blinks at loss of control signal or data errors gelb RDM DMX RDM programming active blinks at DMX RDM traffic rot TEMP Blinks at overtemperature of...

Page 6: ...ode each output each relay inclu ding the safety slot can have its own individual start address Thus seven addresses must be set to configure the complete module The SubDevice mode allows to assign mu...

Page 7: ...inductive loads such as transformers or solenoids requires lower loads we strongly recommend not to exceed 50 of the resistive load data Besides contacts may burn due to inductive spikes and sparks Ma...

Page 8: ...parameters Start Address DMX Personality or DMX HOLD Mode have been modified using DMX RDM the address switches become inactive blocked To re enable start address switches temporarily set any address...

Page 9: ...R EP For standard RDM PIDs pls refer to the RDM manual available from www manuals soundlight de All notations refer to data presented in hexadecimal format and examples are demonstrated with the JESE...

Page 10: ...Parameter Slot number Monotime where Slot number 0001 Slot no 1 Slot number 0002 Slot no 2 Slot number FFFF all Monotime 01 7F 25ms steps FF bistable Mode Press GET to display the current setting Exa...

Page 11: ...rt address We recommend t make no changes The INTERNAL PATCHING function allows to override these allocations This will be helpful when both relays shall be trig gers from the same data slot eventuall...

Page 12: ...can be freela activated and de activa ted at your option The sensor inputs will disable outputs when the sensor signal is beyond the set minimum and maxi mum values The DMX trigger slot will disable...

Page 13: ...FF 255 timecount 25ms Example The saftey supersision for relay 2 shall be engaged after 2 seconds SET PID C0F4 00 02 50 Calculation 2 seconds is 80x 25ms 80 dec is 50 hex 50 Most RDM controllers requ...

Page 14: ...ata cable is used and the shield is connected properly to the GND pin Shield must never make contact to other signal lines FCC Statement This product has been tested and complies with the specificatio...

Page 15: ...e Load manuals from our support site www manuals soundlight de Accessories Setting the DMX start address the DMX personality or the DMX HOLD mode and other parame ters requires a suitable DMX RDM cont...

Reviews: