4
SDAT Serial Data
5
LED Error
6
LED OK
7
SDAI Serial Data Input
8
LED RDM
9
GND, 0.0VDC
10
nc
CN7
External Sensors (Cage Clamps)
1
blue
GND 0.0VDC
2
grey
Sensor 1
3
grey
Sensor 2
4
grey
Sensor 3
5
red
Vcc +5.0VDC
Important Notice:
Please make sure, that all control voltages conected to terminals
CN1, CN5 and CN7 must be compatible to digital TTL logic and
never exceed 5VDC. Higher voltages are likely to damage the
connected internal components.
Signal Indicators
Four status LEDs will indiate the decoder status:
green:
OK
DMX Signal OK
A valid DMX signal is being received.
rot:
ERROR
Blinks at loss of control signal or data errors.
gelb:
RDM
DMX RDM programming active; blinks at DMX RDM traffic
rot:
TEMP
Blinks at overtemperature of extenal sensors
slow blinking at violation of lower limit
fast blinking at violation of upper limit
Depending on address board used, some indicators are also available on the start address board.
Adressboard
The relay module 5202R-EP has been preset to start
address #001 and thus occupies DMX data slots
1...3. To change the slot allocation, the interface must be pro-
grammed. This can be done using a standard DMX RDM con-
troller (we suggest to use the JESE GET/SET controller) or a
optional start address board 3006P-SD or 3008P-SD.