9
MN1617
A6
Unit Size
Reduction Stage
Pints
Liters
38
2
2.5
1.2
3
2.5
1.2
48
2
3.8
1.8
3
3.8
1.8
58
2
5.9
2.8
3
5.5
2.6
68
2
8.0
3.8
3
7.8
3.7
88
2
16.9
8.0
3
16.3
7.7
108
2
25.4
12.0
3
24.7
11.7
128
2
45.6
21.6
3
45.0
21.3
148
2
67.0
31.7
3
65.9
31.2
168
2
104.0
49.2
3
102.3
48.4
A6
Unit
Size
Reduction
Stage
Input
Reducer
Pints
Input
Reducer
Liters
Primary
Reducer
Pints
Primary
Reducer
Liters
68
4
0.5
0.3
9.5
4.5
5
1.3
0.6
9.5
4.5
88
4
1.0
0.5
18.4
8.7
5
2.7
1.3
18.4
8.7
108
4
1.0
0.5
28.9
13.7
5
2.7
1.3
28.9
13.7
128
4
2.2
1.1
48.3
22.9
5
2.7
1.3
48.3
22.9
148
4
2.2
1.1
70.7
33.5
5
2.7
1.3
70.7
33.5
168
4
2.2
1.1
105.6
50.0
5
4.9
2.3
105.6
50.0
Motorized Shaft Mount (MSM) Reducers and Integral Gearmotors
These mounting arrangements are for all output configurations and output shaft types.
IMPORTANT: When ordering, please specify mounting position for correct oil quantity. In cases of mounting position other than
shown here with regard to the oil quantity, please reference the Incline Mounting page in the Quantis Engineering Catalog, and contact
Application Engineering.
NOTE: The oil volumes shown are approximate values and cannot be used to correctly set the reducer oil level. ALWAYS fill
the reducer to the correct oil level plug and recheck in 1 week.
A6 – Horizontal – Wall Mount
Oil Level
Ventilation
Oil Drain
Sensor
NOTES:
All MSM 38 units are sealed for life and furnished with only one plug for filling and draining.
4 and 5 stage reduction reducer consists of two reducers assembled to each other, the Input Reducer and the Primary Reducer. The reducers are
sealed from each other and require different oil levels per the chart.
* Hole location on opposite side of reducer.
A
*
*
A
*
REQUIRES
PIPE
EXTENSION
*