background image

- 6 -

<Operation Test>

· When testing after assembly, check the operation by touching the manual wash button.

· In case of water leakage or an emergency, quickly turn it off by pressing the power button.

· When water is sprayed on the defecation board, turn the nozzle by hand to adjust the 

  spray angle.

· When the sensor is activated, the green light flashes and water is sprayed after 2 minutes.

· When the washing water quantity increase switch is turned on, the spraying quantity

  increases from 1,000cc to 1,500cc.

· In the case of direct type, when the increase switch is turned on, the spraying quantity is

  increased two folds from 1,500 cc to 3,000 cc.

· It is normal for water to accumulate in the collecting channel and it serves as a sewer odor

  backflow prevention trap.

· If the blue light is not turned-on after plugging in the sensor jack, press the power button to

  reset again.

· The defecation board and main body work normally when it is horizontal, so if the floor is

  sloped, use the rubber plate to level it

Assembly of the Main Body

Waste Water Container Connection

and Water Quantity Increase Switch

Lift the main body and place it

on the square collecting channel.

Put the silicone hook on the

bottom so that the lid does

not come off.

Insert the transparent inlet

pipe into the gray silicone for

about 1cm each.

Turn the lid and connect it to

the waste water container.

After plugging in the sensor jack,

connect the power jack from

the back.

There is a water quantity increase

switch and a power jack on

the back.

<3 Steps of Separation: 1.Power jack 2.Sensor jack 3.Inlet pipe>

Main Body assembly and 

Operation Test

Stop for 3 seconds, then auto wash for 2nd time.

Summary of Contents for HAPPYLOO H20GW

Page 1: ...HAPPYLOO Flush Automatic Defecation Board for Dogs User Manual ...

Page 2: ...embly Parts and Product Features How to Assemble the Defecation Board Main Body Assembly and Operation Test About LED Colors and Sensors Precautions and Notes Check Q A Appendix About dogs MEMO Customer Center 3p 4p 5p 6p 7p 8p 9 10p 11p 12p Index ...

Page 3: ...r plug with wet hands It is the cause of electric shock Do not use damaged power cords plugs or loose outlets Make sure that there are no foreign substances such as dust or water in the contact area of the power plug or button Precautions When Using Happyloo Direct Type Never disassemble repair or modify the main body at your discretion For direct connection type please follow the instructions of ...

Page 4: ...d when the dog urinates and automatically cleaned after 2 minutes It is a pleasant eco friendly system with no odor and no waste There is no movement so the dog can use it easily and comfortably The water filling amount is 10L and it can be used 10 times 1L each time It is convenient to clean up with a simple defecation board separation within 10 seconds There is an option for a 26cm tall male sta...

Page 5: ...ver with screws Tighten the nozzle by turning the screw from the bottom Connect a short transparent hose through the hook and plug it into the silicone Make sure the sensor line passes in the upper left corner Insert the rubber feet into the 3 legs with arrows Insert the fitting deeply into the 2 inlets Pass the transparent hose and sensor line through the hook When the screw is tightened the tran...

Page 6: ...thebluelightisnotturned onafterplugginginthesensorjack pressthepowerbuttonto resetagain Thedefecationboardandmainbodyworknormallywhenitishorizontal soiftheflooris sloped usetherubberplatetolevelit Assembly of the Main Body Waste Water Container Connection and Water Quantity Increase Switch Lift the main body and place it on the square collecting channel Put the silicone hook on the bottom so that ...

Page 7: ...rol orstronglight Maketheeavesbyapplyingwidetapeonthetoptopreventwaterfromflowingintothesensorjack Thesensorjackissensitive soifthereismoistureorwater wipeitdrybeforeinsertingit Themalestandisamaterialthroughwhichinfraredrayspass Ifthereisanyforeign substanceonthefrontofthereceiver wipeitclean Artificial intelligence LED judging by color Errorless facing infrared sensor Sensor transmitter Sensor r...

Page 8: ...thegraysilicone insertonlyabout1cm 3 Whenrefillingthemainbodywithwater emptythewastewatercontainercompletelyso thatitdoesnotoverflow 4 Thebluelightisreadyforautomaticcleaning Whenthesensorisdetected thegreen lightflashesandwaterissprayedafter2minutes 5 Extendthedischargehoseand whenthepumpsoundisloudduringtheinitialoperation anditspins pulloutthehoseconnectionforawhileandthenplugitinagainafterthea...

Page 9: ...elicioussnackintheinnercornerfordogs tosteponthemeshandplay Then secondly cutthepadinto to andputalittle urineandputitonthemeshtofacilitatetraining Whattodowithurineonthemesh A Ifyousprayanautomaticspraytocleantheurinefromthemesh iftherearefeces onthemesh waterwillgetonthefeces causingabiggerproblem Happyloo handlesalargeamountofurine about30 100cc whichfallsunderthemesh Urine onthemeshisonlyafewd...

Page 10: ...n ttraindefecationorothertrainingproperly Keepadistanceofat least3meters Thecleaningpowerseemsweak can titbecleanedmorestrongly A Ifyouuseapowerfulpump itwillnotonlymakealoudnoise butthewaterstream ofthewashingwaterissostrongthatitbouncesoffthelegsofthemesh andwater getsonthefeces makingitmoretroublesome Thebiggestreasonfortreatingurine withwateristoremovetheterriblesmell sothecurrentwashingpoweri...

Page 11: ... 11 MEMO ...

Page 12: ... receipt Simple receipt is not effective Damage or breakdown due to negligence in use or connection methods other than our products and products recognized by us Damage or breakdown due to fire earthquake wind water damage lightning and other natural disasters or pollution damage due to salt abnormal voltage etc Damages and breakdowns caused by remodeling and disassembly are in principle not to be...