background image

DogWatch

®

 MB-2

Product Features and Operating Instructions

The DogWatch

®

 MB-2 is a 

dual function transmitter designed to be used either with or without an 

attached boundary wire. 

Troubleshooting

If your pet enters the signal field without responding to the correction signal, make sure that both the 
transmitter and the receiver collar are “ON” and working. If both the transmitter and the receiver are 
functioning properly, you may need to increase the signal range on the transmitter (or the wire) or 
increase the correction level on the collar. Reminder: Never adjust the transmitter or the correction 
level while your pet is wearing the receiver collar.
Receiver

Check to see if the transmitter is turned ‘ON’.

Take the receiver collar off the dog and check the receiver by placing the test light on the

 

contact posts while holding the receiver next to your wireless transmitter or the boundary wire. If

 

your test light lights up, your receiver is working properly. Be sure not to touch the contact posts.

Make sure the collar fits and the contact points on the receiver actually touch your pet’s skin.

Be sure the receiver battery is inserted correctly.

Replace the battery as needed. Average battery life varies depending on use

.

Typical battery life is: R7 receiver = 6 months. R9 receiver = up to 2 years. SmartCollar = up to 1 year.

Transmitter

Check to see if the transmitter is plugged-in and turned “ON”. If functioning properly, the Status
Light should be illuminated solid green (or blinking green depending on the Frequency setting.)

If using a wire, make sure the wire is properly connected and is separated to create a Signal
Field. Make sure the end is stripped and twisted together to create a continuous signal loop.

Check the Range Setting on the back of the transmitter. Increase the range if necessary. Too small
a signal field may allow your pet to get too close to the boundary area before receiving a warning.

1

Signal Range

 

Signal range is the 

distance the signal radiates

 from the transmitter or the 

boundary wire.

Turn the knob toward the ‘Max’ to increase the signal range.
This increases the size of the signal field.

Turn the knob toward the ‘Min’ to decrease the signal range.
This decreases the size of the signal field.

Never adjust the signal range while your pet is wearing the receiver collar. 
Always test the signal field and mark the edge of the field with warning flags 
before allowing your pet near the boundary area.
Frequency 
This switch controls the broadcast frequency of the signal. 
Do NOT change this setting. It is for DEALER USE ONLY.

Turning ON/OFF - Status Light

Press the Power Button to turn the unit ON.

 The Status Light will illuminate green 

indicating the unit is ON. The green light indicates that the signal is being sent. 

When using a boundary wire, the Status Light glows green only when there
is a 

continuous signal loop

. See instructions on page 3.

Note: The green light may either be steady green or blinking green. This depends 
on the Frequency setting of the transmitter.

Press the Power Button to turn the unit OFF

. A red light will illuminate indicating 

the unit is powering OFF.

Top

Controls

Power 
Button

Bottom

NOTE: 

Do not set the transmitter on or near large metal objects.

How the System Works

The MB-2 transmits a silent radio signal that is recognized by a special 

receiver collar

 worn by your pet. 

• When used 

without an attached boundary wire, the signal is transmitted a set distance from the

transmitter. The signal can be adjusted from 18 inches to 13 feet in diameter to create a pet-free
avoidance area.

• When used 

with a boundary wire, the signal comes from the wire. The wire may be installed to the

shape and size you need to create either an 

avoidance area (to keep your pet out of an area) or a

containment area (to keep your pet within an area).

At the edge of the signal, there is a 

warning zone. As your pet approaches the warning zone, the receiver 

collar starts ‘beeping’ to alert your pet that he is too close to the boundary. With training (page 3), your 
pet learns that if he goes beyond the warning zone, the beep is quickly followed by a ‘correction’ (an 
unpleasant, but safe, sensation from the receiver collar). Your pet will learn to stay away from areas he 
associates with the warning beep.

This device complies with part 15 of the FCC Rules and with Industry 
Canada rules. Operation is subject to the following conditions: (1) This 
device may not cause harmful interference, and (2) this device must 
accept any interference received, including interference that may 
cause undesired operation.
Le présent appareil est conforme à la partie 15 régles FCC et est 
confirme aux CNR d’Industrie Canada applicables aux appareils 
radio exempts de licence. L’exploitation est autorisée aux conditions 
suivantes: (1) l’apppareil ne doit pas produire de brouillage, et  
(2) l’utilisateure de l’appariel doit accepter tout brouillage 
radioélectrique subi, même si le brouillage est susceptible 
d’en compromettre le fonctionnement.
DogWatch products are lead-free and compliant with the  
Reduction of Hazardous Substances (RoHS) initiative.
DogWatch Products are protected under U.S. Patent  
numbers: 6,360,698; 6,467,435; and 6,825,768

2 Year Warranty

To see warranty information and submit Warranty Registration: 

www.dogwatch.com/support

REPLACEMENT BATTERIES AND COLLARS

Typical battery life is approximately 2 years but may 
vary depending on use. For replacement batteries and 
additional collars, contact your authorized DogWatch 
Dealer or visit 

www.dogwatch.com/dogwatch-store

 

NOTE: The use of any battery other than a battery 
authorized by DogWatch Inc., can cause erratic 
operation of the receiver or could cause permanent 
damage and may void the Warranty.

Modifications or changes to this equipment not expressly 
approved by DogWatch, Inc., may void the user’s authority 
to operate the equipment. 

Wall Mount Guide

Cut template from the 
booklet and tape to 
wall to drill holes. 

2”

7/64

th

 (#36) drill  

[2 places]

If mounting to drywall 
with no wall stud, be sure 
to use the plastic anchors 
provided.

Status 
Light

Wire 
Terminals

©2020 Printed in USA. All rights reserved.    

295104 Rev. A  12-20

Reviews: