User Information
Climbing formwork 150F
Structural design
13
999775002 - 02/2020
Structural design
Loading data
Anchoring on the structure
Imposed loads
Dimensioning the suspension point
Service loads
V ... permitted vertical load: 35
kN
H ... permitted horizontal load: 65
kN
The required
cube compressive strength
of the con-
crete at the time of loading must be
specified
sepa-
rately for each project
by the structural designer
. It
will depend on the following factors:
▪
load actually occurring
▪
length of stop anchor or pigtail anchor
▪
reinforcement / extra reinforcement steel
▪
distance from edge
The introduction of the forces, the transfer of these
forces into the structure, and the stability of the overall
construction, must all be verified by the structural
designer.
The required cube compressive strength f
ck,cube,current
must be at least 10 N/mm
2
, however.
9775-256-01
V
H
A
150 kg/m
2
B
300 kg/m
2
C
75 kg/m
2
9775-200-02
A
B
C