TROUBLESHOOTING GUIDE
WARNING
7RKHOSSUHYHQWSHUVRQDOLQMXU\DOZD\VUHOHDVHSXPSSUHVVXUHDQGGLVFRQQHFWKRVHVIURPSXPS
EHIRUHPDNLQJUHSDLUV
Refer to the appropriate pump parts list during troubleshooting. Repairs must be performed in a dirt-free envi-
URQPHQWE\TXDOL¿HGSHUVRQQHOIDPLOLDUZLWKWKLVHTXLSPHQW
PROBLEM
CAUSE
SOLUTION
3XPSORVLQJSUHVVXUH
.
1. System components
leaking.
1. Repair or replace as
necessary.
2. Directional control valve
leaks or not adjusted
properly.
2.* Reseat, repair, or replace
directional control assembly
and correctly adjust.
3. Fluid leaking past outlet
check seat(s).
3.* Check for dirt. Reseat pump
body and/or replace
poppet(s) or ball(s).
+DQGOHULVHVDIWHUHDFKVWURNH
1. Fluid leaking past outlet
check seat(s)
1.* Check for dirt. Reseat pump
body and/or replace
poppet(s) or ball(s).
3XPSQRWGHOLYHULQJÀXLG
/RZÀXLGOHYHOLQUHVHUYRLU
&KHFNÀXLGOHYHOSHU
instructions.
,QWDNH¿OWHULVGLUW\
2. Remove reservoir and
clean.
3. Seats worn and not seating
properly.
3.* Repair seats or replace
pump body.
3XPSGRHVQRWUHDFKIXOOSUHV
-
sure.
/RZÀXLGOHYHOLQUHVHUYRLU
&KHFNÀXLGOHYHOSHU
instructions
2. System components
leaking.
2. Repair or replace as
necessary.
3. Directional control valve
leaks or not adjusted
properly.
3.* Reseat, repair, or replace
directional control assembly
and correctly adjust.
4. Improperly adjusted relief
valve.
4.* Readjust.
5. Fluid leaking past inlet or
outlet checks or high
pressure piston seal
damaged.
5.* Reseat or repair inlet or
outlet checks or replace
high pressure piston seal.
3XPSKDQGOHFDQEHSXVKHG
GRZQVORZO\ZLWKRXWUDLVLQJ
WKHORDG
1. Inlet checks are not seating.
1.* Check for dirt and/or reseat
valve seats.
2. Damaged piston assembly
or piston seals leaking,
2. Damaged piston assembly
or piston seals leaking.