4
999265002 - 12/2017
Original Operating Instructions
Dokamatic lifting strap 13.00m
Lifting of stacks
with strap shoes
To lift
stacked tableform superstructures
, the Doka-
matic lifting strap 13.00m is used
with integrated
strap shoes
.
▪
Dokamatic table
▪
Dokaflex table
Max. number of elements in stack:
➤
Push the strap shoes of the Dokamatic lifting strap
onto the secondary beam, firmly and completely.
➤
Mount the strap shoes of the second lifting strap in
the same way.
without strap shoes
To lift
e.g. stacked Framax panels
, the Dokamatic lift-
ing strap 13.00m is used
without strap shoes
.
▪
Framax panel
▪
Frami panel
▪
Formwork element FF20
▪
FF100
tec element
▪
Frame Xbright
NOTICE
Risk of damage to the bottom table if the Lifting
strap is used without strap shoes.
Dokamatic table
6 elements
Dokamatic S table
4 elements
Dokaflex table
5 elements
NOTICE
The strap shoes must
always
be mounted to
the 2nd secondary beam from the edge of the
element.
A
Dokamatic lifting strap 13.00m
B
Strap shoe
Both strap shoes must be mounted to oppo-
site ends of the same formwork beam!
9767-281-01
9767-266-01
A
B
2
1
NOTICE
With
custom tables
, allowance must be made
for the following points:
▪
secondary beams may cantilever out further
▪
greater weight
▪
oblique pull of the lifting strap
Reinforce the secondary beams by e.g.
nail-
ing on a strip of formwork sheeting
.
WARNING
➤
The Lifting straps 13.00 m may only be used
as shown here if there is no risk of the straps
sliding towards one another, or of the load
being displaced.
9767-349-01
9764-235-01