102
999811202 - 04/2019
Wall formwork
User Information
Framed formwork Framax Xlife plus
➤
Use a wedge to tighten the formwork against the
wall/slab.
➤
Fit the anchors.
➤
Detach the gang-form from the crane.
E
Wedge
F
Opposing formwork
Before disconnecting from the crane:
➤
Do not disconnect the panel from the crane
until a large enough number of form ties
have been installed to keep it safely in the
upright.