User Information
Framed formwork Framax Xlife plus
Wall formwork
79
999811202 - 04/2019
Inter-panel connections for increased tensile loads
As a rule, only
2 clamps are needed per 2.70 m
and
3
clamps per 3.30 m
formwork height as a tension link
between the panels.
However, where
increased tensile loads
need to be
sustained near outside corners and stop-ends,
extra
clamps are needed
.
Near stop-ends
a ... up to 40 cm
b ... 1.35 m
X1
...
1 additional clamp
Near outside corners
a ... up to 40 cm
b ... 1.35 m
X1
...
1 additional clamp
Wall thicknesses up to 40 cm:
For each panel joint up to 1.35 m:
▪
1 extra clamp
9 - -01
8112 264
b
X
1
a
98112-278-04
b
X
1
b
X
1
a
a