80
999811202 - 04/2019
Wall formwork
User Information
Framed formwork Framax Xlife plus
Stop-end formwork
There are
3 ways
of
forming stop ends
:
▪
with universal panel
▪
stop-end waler tie
▪
with universal waling
Note:
For details regarding extra inter-panel connections on
stop-ends (for increased tensile loads) see 'Inter-panel
connections for increased tensile loads'.
with universal walings
Universal walings make it possible to form
stop-ends
continuously across any thickness of wall
.
They are mounted using universal fixing bolts and
Super plates 15.0 fixed through the cross boreholes in
the panels.
with stop-end waler ties
The stop-end waler ties make it possible to form stop-
ends continuously from wall thicknesses of 15
cm to
45
cm.
a ... 15
to 45
cm
A
Framax universal waling
B
Framax universal fixing bolt + Super plate 15.0
C
Framax Xlife plus panel (panel width > 0.30m)
D
Doka tie rod system
Framax universal waling:
Permitted moment: 5.2 kNm
Framax universal fixing bolt:
permitted tensile force in the cross borehole of the
Framax Xlife plus panel: 25.0
kN
9 -20 -08112
4
1
9 -20 -0
8112
4 2
A
C
D
B
A
Framax stop-end waler tie
B
Framax Xlife plus panel
98112-200-01
98112-200-02
a
A
B
Summary of Contents for Framed formwork Framax Xlife plus
Page 2: ...2 999811202 04 2019 User Information Framed formwork Framax Xlife plus ...
Page 51: ...User Information Framed formwork Framax Xlife plus Wall formwork 51 999811202 04 2019 ...
Page 70: ...70 999811202 04 2019 Wall formwork User Information Framed formwork Framax Xlife plus ...
Page 117: ...User Information Framed formwork Framax Xlife plus Wall formwork 117 999811202 04 2019 ...
Page 127: ...User Information Framed formwork Framax Xlife plus General remarks 127 999811202 04 2019 ...
Page 139: ...User Information Framed formwork Framax Xlife plus Component overview 139 999811202 04 2019 ...