120
999805802 - 03/2016
Structural design – Lifting unit attached on one side
Original Operating Instructions
Platform SCP
Structural design – Lifting unit attached on one side
Loading data
The statical design for the Platform SCP must allow for
two different load situations:
▪
Loads imposed in the statically anchored state, i.e.
while construction tasks are being carried out.
▪
Loads occurring during the lifting operation, i.e. while
the Platform
SCP is being moved into a new working
position.
Max. permitted loads
Two Brackets SCP (top)
One Bracket SCP (bottom)
static
during lifting
2 x V
1
(300
kN) = 600 kN
V
2
... 400
kN
98058-459
-01
V
1
V
1
98058-459
-02
V
2
☞
The introduction of the forces, the transfer of
these forces into the structure, and the stability
of the overall construction, must all be verified
by the structural designer.