29
999805802 - 03/2016
Minimum wall thicknesses
Attaching latch-boxes to the
formwork
➤
Fix a piece of formwork sheeting measuring
33.5x10cm onto the formwork with screws or pin-
nails (to hold the Box for latch in the right position).
➤
Drill diam. 30
mm holes in the form-ply (position as
shown in shop drawing / assembly plan).
➤
Fit on a Form-ply protector 22mm.
➤
Twist two Tie rods 15.0 into the sockets of the Box
for latch, until fully engaged.
➤
Place the Box for latch over the position-holder and
fix it with Super plates 15.0.
Fitting tolerances
Dimensioning the suspension point
for one Box for latch
for back-to-back Boxes for latch
a ... min. 160
mm
b ... min. 320
mm
A
Box for latch 15.0
B
Position-holder (e.g. piece of formwork sheeting, 33.5x10cm)
C
Form-ply protector 22mm
D
Super plate 15.0
E
Tie rod 15.0 (length 500
mm)
F
E.g. plank
☞
The positions of the latch-boxes must be
defined at an early stage, when the formwork is
being planned and assembled.
The Doka beams and multi-purpose walings of
the formwork must not cover the hole drilled for
the suspension point.
98058-415
-01
a
98058-415
-02
b
98058-414-01
C
A
E
B
D
F
☞
▪
Inclination of base beam: max.
0.50%
- Example:
Width of shaft: 2000
mm
Max. height mismatch of two opposite
Boxes for latch: 10
mm
a ... width of shaft
b ... height mismatch
▪
Horizontal alignment of latch-boxes
- Skew between the two sides: max.
4 mm.
c ... max. 4
mm
The required
cube compressive strength
of the con-
crete at the time of loading must be
specified sepa-
rately for each project by the structural designer
and will depend on the load that actually occurs.
The introduction of the forces, the transfer of these
forces into the structure, and the stability of the overall
construction, must all be verified by the structural
designer.
98058-413-04
b
a
98058-413-06
c
Summary of Contents for Platform SCP
Page 2: ...2 999805802 03 2016 Original Operating Instructions Platform SCP ...
Page 3: ...Original Operating Instructions Platform SCP 3 999805802 03 2016 ...
Page 31: ...Original Operating Instructions Platform SCP Anchoring on the structure 31 999805802 03 2016 ...
Page 61: ...Original Operating Instructions Platform SCP Start up phases 61 999805802 03 2016 ...
Page 114: ...114 999805802 03 2016 Design variants Original Operating Instructions Platform SCP ...