Original Operating Instructions
Platform SCP
Pre-assembly
77
999805802 - 03/2016
Grille-beam unit
Assembling the longitudinal members:
➤
Lay down hardwood blocking.
➤
Set down Grille beams U300 on the hardwood block-
ing.
➤
Mount facade profile connector or railing profile at
the edge area of a grille-beam unit.
➤
Position joint plates on the grille beams.
Assembling the transverse members:
➤
Set down Grille beams U300 on the joint plates.
➤
Mount facade profile connector or railing profile at
the edge area of a grille-beam unit.
☞
Important note:
Guide value for one grille-beam unit:
▪
Area approx. 100
m
2
▪
Consider what craneage is available!
Note the weights stated in the final drawing or
assembly drawing!
A
Grille beam U300
B
Joint plate WU30
C
Joint plate WU30F
D
Joint plate U300
E
Sleeper
98058-444-01
A
B
C
D
E
Joint plate WU30
Joint plate WU30F
Joint plate U300
98058-444-02
98058-444-03
98058-444-04