Erection Guidelines for 4 Leg Stair Tower
59
999817902 - 10/2022
Step 6
➤
For further assembly of the stair tower, the use of
personal protective equipment against falls from a
height (PPE) is required. Suitable safety harness
connection points are located in the 'Safety Harness
Connection Points' section.
➤
From the stair landing and the temporary working
level, the other vertical standards 2m, the vertical
diagonals and the ledgers of the next scaffold level
are installed. On the inside of the staircase, the inner
guardrail is attached and secured to the stringers
with the hammerhead screws.
98179-243-01