12
999808702 - 11/2019
System description
User Information
Load-bearing tower Staxo
100
eco
The Staxo
100
eco frame in detail
Interconnection system on Load-
bearing tower Staxo
100
eco
▪
Easy, safe interconnection using the couplers and
spring-locked connecting pins 16mm.
1)
Fix a coupler in the top frame, using a Spring locked
connecting pin 16mm.
2)
Place this frame on top of the one below it.
3)
Secure it with a Spring locked connecting pin
16mm.
Safety catch
▪
tried-and-tested interconnection system (captive)
▪
secures the diagonal crosses
▪
two defined positions (closed – open)
Connecting the couplers
a ... max. 16 cm (exception: where tubes are being connected for
constructional design purposes)
c ... Diameter 75
mm
Profile form
▪
low weight, yet high load-bearing capacity
▪
sturdy
Profile seal
▪
protects against damage
▪
sliding contact surface for nuts
NOTICE
Only Staxo
100 frames and Staxo
100
eco
frames fulfil the capacity ratings stated in this
document!
A
Coupler
B
Spring-locked connecting pin 16mm
C
Staxo
100
eco frame
9718-218-01
A
B
C
Closed
Open
A
Transition swivel coupler 48/76mm.
This type of link is not in conformity with DIN
4421 (DIN
EN
74).
No loads may be introduced parallel to the Staxo tubes.
98087-206-01
98087-206-02
98087-205-02
c
a
A