User Information
Load-bearing tower Staxo
100
eco
System description
23
999808702 - 11/2019
Practical examples
Linking towers
Placing scaffold planking between towers
Erecting guard rails in frame plane
Note:
In the bracing-strut plane, guard rails may be erected
using scaffold tubes 48.3mm and Transition swivel cou-
plers 48/76mm.
98087-203-03
B
D
98087-204-01
A
C
98087-203-02
B
C
A
Staxo
100 planking strut 1.00m
B
Staxo
100 planking strut 1.50m
C
Scaffold planking
D
Diagonal cross (where statically required)
E
Scaffold tube 48.3mm
F
Transition swivel coupler 48/76mm
98087-202-04
B
98087-202-05
E
F