User Information
Load-bearing tower Staxo
100
eco
General
47
999808702 - 11/2019
Bracing waling connector WS10
The Bracing waling connector WS10 is used for bracing
load-bearing towers erected on ground which has suffi-
cient load-bearing capacity but in which it is not possi-
ble to fix tension anchoring.
It is also possible to brace several load-bearing towers
to one another to transfer the horizontal loads jointly.
Bracing individual towers in the bracing-strut and
frame planes
Note:
Separate towers may also be braced in the frame plane
or bracing-strut plane only.
Close-up
Note:
The Bracing for load-bearing towers is attached to the
multi-purpose waling directly by means of a spindle
unit, without a 'Shoe (complete)'.
Permitted bracing force [kN]
Bracing waling connector WS10
A
Bracing waling connector WS10
B
Multi-purpose waling WS10 Top50 2.25m
C
Tie rod 15.0mm galvanised ...m
98087 227
- -01
98087-227-02
A
B
B
C
D
E
C
G
G
H
H
F
C
G
D
Super plate 15.0
E
Bracing for load-bearing towers – without 'Shoe (complete)'
F
Eye-lug anchor 15.0 without tie rod
G
Connecting pin 10cm and Spring cotter 5mm
H
Extra safeguard against slippage (end-stop) with Connecting pin
10cm and Spring cotter 5mm
Bolted on through the
upper
bore
(Ø
21
mm) of the screw-jack unit
Bolted on through the
lower
bore
(Ø
27
mm) of the screw-jack unit
50.0
40.0
A
Screw-jack unit
Permitted tensile force: 50
kN
➤
When calculating the leg loads on the Load-
bearing tower, allow for the additional forces
from the bracing!
Tr845-204-02
A
Tr845-204-01
A