User Information
Load-bearing tower Staxo
100
eco
General
55
999808702 - 11/2019
Steel primary beams
The following tables will be helpful to you when you are
planning load-bearing tower superstructures consisting
of steel primary beams and Screw jack U-heads, Heavy
duty screw jacks 70 top or Swivel bearing plates for
Screw jack U-head.
Usage conditions for Doka series walings
1)
Hardwood support
(A)
needed.
The bevelled edges prevent it resting in the curved radius zone.
This results in a max. available width of 188
mm.
Usage conditions for various I-section girders
Doka series walings
Width x
height
[mm]
Unsecured
Max. width = 165
mm
Secured centrally
(necessary from 12%)
Max. width = 165
mm
Multi-purpose waling WS10
Top50
153 x 100
Yes
Yes
Multi-purpose waling WU12
Top50
163 x 120
Yes
Yes
Facade waling WU14
172 x 140
Yes
1)
Yes
1)
Multi-purpose waling SL-1
WU16
183 x 160
Yes
1)
Yes
1)
System beam SL-1
226 x 240
No
No
Tr777-200-01
Tr777-201-01
Tr770-201-03
A
Selection of I-girders
Width x
height
[mm]
Unsecured
Max. width = 165
mm
Secured at side
(necessary from 12%)
Max. width = 150
mm
I 380
149 x 380
Yes
Yes
I 425
163 x 425
Yes
No
IPE 300
150 x 300
Yes
Yes
IPE 330
160 x 330
Yes
No
IPBI 140
140 x 133
Yes
Yes
IPBI 160
160 x 152
Yes
No
IPB 140
140 x 140
Yes
Yes
IPB 160
160 x 160
Yes
No
Tr777-202-01
Tr777-203-01