User Information
Load-bearing tower Staxo 100
System description
21
999804302 - 02/2018
Frame-sizes up to 1.20
m
1.20m and 0.90m frames are possible here.
Table A
Choose the right diagonal crosses for the distance between the
frames.
The schedule of materials does not include scaffold planking units.
The scaffold planking units have to be planned separately for each
set-up configuration. Provided they are located in the same level,
they replace the Diagonal crosses 9.xxx needed for horizontal brac-
ing. This reduction in the number of diagonal crosses needed must
be allowed for in the schedule of materials.
NOTICE
▪
The minimum values h
min.
given in Table A
are only applicable if the biggest possible
frame is always used in the base section.
▪
The
lowering distance of 6
cm
is already
allowed for in Table A!
▪
L
K
and L
F
are in accordance with the struc-
tural design. In some cases, the structural
design will permit greater extension lengths
- see Tables B and C in the section headed
'Height adjustment'.
▪
Greater extension lengths are possible (up
to max. 45
cm) if the head units and/or base
units are given suitable scaffold-tube brac-
ing.
▪
In principle, it is possible to use Heavy-duty
screw jacks 70 and Heavy-duty screw jacks
70 top. However, when these are combined
with the small frames, you must observe the
limitations given in Tables B and C of the
section headed 'Height adjustment'.
Fixed height of frame F
h
[m]
L
K
= max. 30
cm
L
F
= max. 30
cm
Basic items
4-way screw-jack head or Screw jack U-head
Screw-jack foot
Staxo
100 frame 0.90m
Staxo
100 frame 1.20m
Diagonal cross 9.xxx
Diagonal cross 12.xxx
h [m]
min. - max.
1.20
1.75 - 1.80
4
4
-
2
1
2
1.80
2.18 - 2.40
4
4
4
-
5
-
2.10
2.32 - 2.70
4
4
2
2
3
2
2.40
2.62 - 3.00
4
4
-
4
1
4
2.70
3.10 - 3.30
4
4
6
-
8
-
3.00
3.22 - 3.60
4
4
4
2
6
2
3.30
3.52 - 3.90
4
4
2
4
4
4
3.60
3.82 - 4.20
4
4
-
6
2
6
3.90
4.12 - 4.50
4
4
6
2
8
2
4.20
4.42 - 4.80
4
4
4
4
6
4
4.50
4.72 - 5.10
4
4
2
6
4
6
98003-220-01
h
h
F
h
L
K
L
F
L
F
98003-113
4.80
5.02 - 5.40
4
4
-
8
2
8
5.10
5.32 - 5.70
4
4
6
4
8
4
5.40
5.62 - 6.00
4
4
4
6
6
6
5.70
5.92 - 6.30
4
4
2
8
4
8
6.00
6.22 - 6.60
4
4
-
10
2
10
6.30
6.52 - 6.90
4
4
6
6
8
6
6.60
6.82 - 7.20
4
4
4
8
6
8
6.90
7.12 - 7.50
4
4
2
10
4
10
7.20
7.42 - 7.80
4
4
-
12
2
12
7.50
7.72 - 8.10
4
4
6
8
8
8
7.80
8.02 - 8.40
4
4
4
10
6
10
8.10
8.32 - 8.70
4
4
2
12
4
12
8.40
8.62 - 9.00
4
4
-
14
2
14
8.70
8.92 - 9.30
4
4
6
10
8
10
9.00
9.22 - 9.60
4
4
4
12
6
12
9.30
9.52 - 9.90
4
4
2
14
4
14
Fixed height of frame F
h
[m]
L
K
= max. 30
cm
L
F
= max. 30
cm
Basic items
4-way screw-jack head or Screw jack U-head
Screw-jack foot
Staxo
100 frame 0.90m
Staxo
100 frame 1.20m
Diagonal cross 9.xxx
Diagonal cross 12.xxx
h [m]
min. - max.
98003-113