User Information
Load-bearing tower Staxo 100
Assembling towers in the upright
39
999804302 - 02/2018
➤
Fit and secure diagonal crosses in the same way as
in the second 'storey'.
Horizontal bracing
➤
Slot diagonal crosses onto the safety-catch bolts of
the horizontal frame tubes, and fix them in place.
Erecting further storeys
➤
Add further frames in the same way as for the 3rd
storey, and brace them in the vertical with diagonal
crosses.
Mount the toeboard
To create a safe workplace, toeboards must be
mounted:
➤
Hook the Staxo
100 toeboards onto the safety-catch
bolts.
➤
Fit the site-provided planks.
➤
Fix the planks with nails.
F
Diagonal cross
To meet particularly stringent safety require-
ments, the ‘mounted-ahead’ railings can be
left in place on all levels (‘storeys’) with scaf-
fold planking units.
NOTICE
If no scaffold planking units are used, or if
these are removed before the tower is finally
put into use, the following rule applies:
Basic rule:
▪
Maintaining correct geometry by fixing a horizontal
diagonal cross in the 1st and last-but-one or last
'storey', and every 10
m.
Additionally as required e.g.
- if there is a horizontal restraint for the tower
(even a temporary one)
- if local loads need to be transferred (e.g. from
attaching the tower to the crane after it has
been ground-assembled in the horizontal)
For detailed design-load information, see the type
test.
F
98003-211-01
K
Diagonal cross
NOTICE
▪
If the load-bearing tower is over 6
m high,
back-stay it or combine it with other towers.
Determining the right plank-length: Centre-to-
centre distance between the frames, minus
10
cm
A
Staxo 100 toeboard
B
Safety-catch bolt
C
Plank
98003-285-01
K
Tr772-203-01
C
A
B