70
999804302 - 02/2018
General remarks
User Information
Load-bearing tower Staxo 100
Permitted load-bearing capacity of Eurex 60
550
Permitted capacities [kN] as a function of the exten-
sion length and the position of the outer tube
(prop category T55 to EN 16031)
*) Position of outer tube
Holding primary beams
Assembly
➤
Place the U-head or four-way head on the prop and
fix with spring-steel stirrup.
Bracing
Swivel couplers Eurex 60 can be fixed at any height on
the outer tube. This means that bracing tubes can be
attached wherever needed.
Examples:
▪
between prop and load-bearing tower frame
▪
between two or more props
▪
to facilitate erection of the prop (as a 'handle' for
workers to hold onto)
Position of
outer tube*)
Prop length [m]
at bottom
at top
5.5
61.8
67.0
5.4
65.0
70.9
5.3
68.5
74.9
5.2
72.1
78.6
5.1
76.0
83.5
5.0
80.3
88.6
4.9
84.0
88.9
4.8
88.9
4.7
4.6
4.5
4.4
4.3
4.2
4.1
4.0
3.9
3.8
3.7
3.6
3.5
at bottom
at top
9745-2 -01
21
9745-2 -01
21
U-head Eurex 60 for steel girders
(e.g. WS10), squared timbers or
formwork beams H20
Four-way head Eurex 60 for sin-
gle or double formwork beams H
20
A
Floor prop Eurex 60 550
B
Swivel coupler Eurex 60
C
Scaffolding tube 48.3mm
9745-201-01
9745-201-01
9745-212-01
9745-203-01
C
B
A