User Information
Load-bearing tower Staxo 100
General remarks
73
999804302 - 02/2018
Combining Staxo 100 with Staxo
NOTICE
In principle, the system frames of the Load-
bearing towers Staxo and Staxo 100 are com-
patible with one another. Ideally, however,
tower frames should each be assembled from
components of the same system (i.e. 'mono-
system'). The diagrams in the User Informa-
tion booklet and type-test only apply to mono-
system tower frames.
If this is not possible, then the following points
must be remembered:
▪
The lower leg loads permitted for the Staxo
system must be assumed.
- Custom applications with permitted
capacities of 85 or 97
kN per leg are not
possible
- No type-test
▪
At the very least, each 'storey' must be
assembled from components of the same
system (because the two systems use dif-
ferent horizontal diagonal braces).
For details regarding structural design, set-up
and use, see the User Information booklet
'Doka load-bearing tower Staxo' !