84
999804302 - 02/2018
General remarks
User Information
Load-bearing tower Staxo 100
Removing and refitting the connection sleeve
Removing
➤
Using e.g. a tie rod, push the connection sleeve
upwards until it hits the stop.
➤
Use a screwdriver to press the spring out of the way.
➤
Pull out the connection sleeve as far as the stop.
➤
Stick a pointed object (e.g. a nail) into the hole in the
connection sleeve until the spring no longer reaches
over the stop.
➤
Completely pull out the connection sleeve.
Safely stow away the loose connection sleeve so that it
can be reinstalled in the Staxo 100 frame when work is
finished.
Installation
➤
Use a screwdriver to press the spring out of the way.
➤
Push the connection sleeve into the frame tube from
below, until it hits the stop (make sure that the spring
(A)
is in the right position)
➤
Use a screwdriver to press the rear stop out of the
way.
➤
Keep pushing in the connection sleeve until the
spring snaps into place.
➤
Press the yellow locking spring towards the outside.
This fixes the connection sleeve in the frame.
The Staxo 100 frame is now back in its as-delivered
condition.
98003-301-01
98003-301-02
98003-301-03
98003-301-04
A
98003-313-01
98003-313-02
98003-313-03