17
17
1.2 Configuration on delivery
Operating mode of BI 5910
Rotary switch A = 0:
- Maximum time to activate remote control
after taking from charger unit 5 sec.
Rotary switch B = 0:
- Sensor inputs S11-S14 and S21-S24 always
active, manual start only with start button on
S42
- Remote control active when control contact
on S32 or S34 is open
- Reset from remote e-stop with remote start
button (+ Infra-red)
Number of frequency channel
Channel 01, 433.100 MHz
Activity monitoring function time period
Standard programming is off.
Number of electronic key
IIndividual number generated at production
and engraved on the key.
Please note on unpacking the number of the
electronic key on the first page of this manual,
with this number an identical key can be
ordered from DOLD.
Configuration of push buttons and outputs
Fixed assignment of push buttons to outputs
(see section 3.3)
Locking of the remote control
The remote control is delivered in unlocked
state (with disabled activity monitoring function
– 99). The activity monitoring function period,
the frequency and the lock of the programming
according to the electronic key can be modified
by a trained user (see section 3.9).
1.2 Configuration on delivery
Operating mode of BI 5910
Rotary switch A = 0:
- Maximum time to activate remote control
after taking from charger unit 5 sec.
Rotary switch B = 0:
- Sensor inputs S11-S14 and S21-S24 always
active, manual start only with start button on
S42
- Remote control active when control contact
on S32 or S34 is open
- Reset from remote e-stop with remote start
button (+ Infra-red)
Number of frequency channel
Channel 01, 433.100 MHz
Activity monitoring function time period
Standard programming is off.
Number of electronic key
IIndividual number generated at production
and engraved on the key.
Please note on unpacking the number of the
electronic key on the first page of this manual,
with this number an identical key can be
ordered from DOLD.
Configuration of push buttons and outputs
Fixed assignment of push buttons to outputs
(see section 3.3)
Locking of the remote control
The remote control is delivered in unlocked
state (with disabled activity monitoring function
– 99). The activity monitoring function period,
the frequency and the lock of the programming
according to the electronic key can be modified
by a trained user (see section 3.9).
Summary of Contents for BI 5910
Page 129: ...129 129 Appendix Appendix...