General installation instructions
Please note the following installation instructions.
Non-compliance results in expiry of guarantee claims.
• horizontal bending radius should not be less
than >= 200 mm
• vertical bending radius should not be less
than >= 50 mm
• Do not bend the modules at sharp angles
• Do not twist the strips during the installation
• Do not throw the roll but unwind evenly, but roll out
evenly on a horizontal surface
• Avoid bringing force to bear on or tensioning the connec-
tions of the strips during installation and secure the
wiring to fully exclude this after installation
• Avoid bringing mechanical forces to bear on any part of
the product during installation
• Exercise particular care when installing lengths in excess
of 1.5 m to prevent damage to the conducting foil or
electronic components
• The materials used will allow changes in length of up to
± 2 mm/m per 10 K temperature difference
Electrical commissioning
• The specific product data sheet and the specifications by
the manufacturers of electronic equipment are binding
in terms of the wiring of LED modules to controllers and
upstream devices