5 BC
2201SS User Manual
www.dolphinsolutions.co.uk
Sensing Range Adjustment
The exact sensing range was pre-set by maker.
You’d better not change it.
If you want to modify the Sensing Range, please proceed the following procedures.
(And please also refer to TIMER ASSEMBLY DRAWING (-) as follows)
First of all, cut off the power supply, please.
Remove the ENCLOSURE / HOUSING of hand dryer.
Remove the outer case of TIMER ASSEMBLY.
Find the SENSING RANGE ADJUSTER inside the TIMER ASSEMBLY and
use tiny screw driver - type or + type to turn round the SENSING RANG ADJUSTER:
(A) Clock--------------
Lengthen the sensing range (+)
(B) Counterclockwise-----
Shorten the sensing range (-)
" "
" "
Lengthen the sensing range (+)
Shorten the sensing range (-)