Sensing Range Adjustment

The exact sensing range was pre-set by maker.
You’d better not change it.
If you want to modify the Sensing Range, please proceed the following procedures.

(And please also refer to TIMER ASSEMBLY DRAWING (-) as follows)

First of all, cut off the power supply, please.
Remove the ENCLOSURE / HOUSING of hand dryer.
Remove the outer case of TIMER ASSEMBLY.
Find the SENSING RANGE ADJUSTER inside the TIMER ASSEMBLY and
use tiny screw driver  -   type or  +   type to turn round the SENSING RANG ADJUSTER:

(A) Clock--------------
      Lengthen the sensing range (+)
(B) Counterclockwise-----
      Shorten the sensing range (-)

"  "

"  "

Lengthen the sensing range (+)

Shorten the sensing range (-)