background image

BC 634 

|  

Dolphin Blue

|  

15

TROUBLE SHOOTING

PROBLEM          INDICATOR        CAUSE 

SOLUTION

Replace batteries

Increase the range with remote

Decrease the range with remote

Replace batteries

Decrease the range or eliminate
cause of reflection

Low batteries

Range is too short

Range is too long ie tap 
has gone into security mode

Batteries are completely used up

Sensor is picking up reflections 

ie tap has gone into security mode

Connectors between the
electronic unit and the solonoid
are disconnected

Debris or scale in solonoid

The central orifice in the
diaphragm is plugged or the
diaphragm is torn

The water supply pressure is
higher than 8 bars

Debris or scale in diaphragm

Sensor is dirty or covered

Sensor is picking up reflections
from the washbasin or another
object

Filter or aerator is clogged

Sensor flashes

continuously when
user’s hands are
within the sensor’s
range

Red light in the
sensor does not flash
once when user’s
hands are within the
sensor’s range

Red light in the
sensor flashes once
when user’s hands are
within the sensor’s
range

Sensor flashes once
when user’s hands are
within the sensor’s
range

Red light in the
sensor does not flash
when user’s hands are
within the sensor’s
range

No water

comes out
of the tap

Water flow
from spout
does not
stop

Water flow
diminished

Connect the electronic unit
connectors to the solonoid

Unscrew solonoid, pull out the
plunger and the spring from the
solonoide and clean them. Use
scale remover material if needed.
When replacing the plunger,please
make sure that the spring is in
vertical position

Unscrew solonoid and clean the
orifice and/or replace diaphragm

Reduce the water supply pressure

Unscrew solonoid, remove
diaphragm and clean or replace.
Use scale remover if needed.

Clean or eliminate cause of
interference

Decrease the range or eliminate
case of reflection

Remove, clean and reinstall

Summary of Contents for BC634

Page 1: ...INSTALLATION AND MAINTENANCE GUIDE BC634 B E H I N D F R E E TO U C H F R E E S OA P D I S P E N S E R Saving soap saving power promoting hygiene Important Read carefully before installing product ...

Page 2: ... Information 5 Pack Contents 6 8 Installation 9 FillingThe SoapTank 10 Settings Adjustment with a Remote Control 11 Batteries Replacement 12 Maintenance Care And Cleaning Of Chrome And Special Finishes 13 Spare Parts List 14 Warranty 15 Trouble Shooting INDEX ...

Page 3: ...er BC 634B Behind mirror Soap Dispenser BC 634E Capacity 1 Litre 33 8 oz Power Supply IP 67 Battery Box for 6xD Alkaline batteries Transformer Soap viscosity 100 3800 cPs Standard discharge 0 8cc Adjustable Sensor range 30 100 mm 10 mm Adjustable by remote control ...

Page 4: ...e of more than 300 mm between the sink and the spout 2 This tap model with an infrared sensor pointing down is not intended to be used together with a sink of a reflective material such as stainless steel 3 If a sink strainer is straight below the tap sensor use a strainer with a non reflective finish do not use a chrome plated one 4 To prevent reflection problems it is recommended to keep a minim...

Page 5: ...th the part names and confirm that the parts are included PACK CONTENTS 4 screws up to 5mm not supplied Product assembly containing Pump with bottle support plate with spout and soap tank IP 67 Battery box for 6 x D alkaline batteries Transformer ...

Page 6: ... mirror compartment for the soap dispenser sensor and spout both The recommended hole size should be 30x50 mm Step 2 Installing the soap dispenser 1 Remove the protective sticker covering the sensor 2 Place the soap dispenser assembly inside the mirror compartment with the spout sticking out of the hole ...

Page 7: ... power source Make sure that the 4 contacts connector is connected properly so that the white o ring is not visible Pay attention If the 4 contacts connectors will not be connected properly the motor will work continuously O ring visible not connected properly Connected properly so that only the groves are visible ...

Page 8: ...wall in the mirror compartment and connect the battery connector For transformer versions Plug the transformer into the electricity socket and make sure the transformer connector is connected Wait about 10 seconds before you put your hands within the sensor range INSTALLATION ...

Page 9: ... soap starts coming out of the soap dispenser spout This operation can also be done using the soap dispenser remote control Refill function 2 Fill in the liquid soap up to the top line 4 Screw the soap tank back to the pump assembly Make sure the tank is secured firmly in place Note Once the soap in the soap tank has reached the bottom line the soap tank should be refilled To refill the soap tank ...

Page 10: ... 0 9 3 1 2 to 1 6 4 2 1 to 2 3 2 ADJ This function allows coming back to soap quantity factory settings Press the ADJ button Indication 2 blinks of the red light in the sensor eye 3Temporary Off Function This function is ideal to perform any kind of activity in front of the sensor without operating the system for example cleaning The soap dispenser will remain shut for 1 minute when this button is...

Page 11: ...lace the battery in battery models 1 Carefully open the battery box place within the mirror compartment using 2 5 mm Allen key 2 Remove the old batteries 3 Replace the used batteries with new D batteries NOTE Do not mix used batteries with new ones BATTERY REPLACEMENT Important Spent batteries should not be disposed of with normal household waste Contact your local authority for information on was...

Page 12: ...rasives or the like Use of any prohibited cleaning or maintenance products or substances could damage the surface of the soap dispenser For surface cleaning use ONLY soap and water then wipe dry with a clean cloth or towel When cleaning bathroom tiles the soap dispenser should be protected from any splattering of harsh cleansers MAINTENANCE ...

Page 13: ...C 07100020 Transformer BC 06522042 Soap dispenser Pump assembly BC 07222001 Remote control BC 07100008 IP67 transformer box BC 06530021 IP 67 Battery Box for 6xd alkaline batteries BC 06530041 Bottle support 1 L BC 07120175 Soap dispenser spout assembly BC 07271023 SPARE PARTS LIST ...

Page 14: ...and wash it under running water 4 Reassemble the parts 5 Reconnect the solenoid valve housing and restore the incoming water supply 6 Make sure that there is no water leakage Care and cleaning of chrome and special finishes DO NOT use steel wool or cleansing agents containing alcohol acid abrasives or the like Use of any prohibited cleaning or maintenance products or substances could damage the su...

Page 15: ...ser s hands are within the sensor s range Red light in the sensor does not flash once when user s hands are within the sensor s range Red light in the sensor flashes once when user s hands are within the sensor s range Sensor flashes once when user s hands are within the sensor s range Red light in the sensor does not flash when user s hands are within the sensor s range No water comes out of the ...

Page 16: ... source female Counter hole Ø 28 34mm Min max thickness 2 27mm 3 8 BSP water supply connector Power Plug in 9 volt transformers or 9 volt battery with low battery warning for other power source options see page 190 191 Product Codes Polished chrome finish Powered by 6 x AAA 9v PP3 battery DB 200C Powered by 9v plug in transformer DB 225C Brushed nickel finish designed to match brushed stainless st...

Reviews: