Preparing installation
33
The DOM devices (with the exception of the external reader unit of the ENiQ
Module Reader) can be installed on standard switch boxes (∅ 60 mm, depth
42 mm). If you do not have a switch box available, you can use the DOM
surface-mounting frame as an alternative (available separately).
Install the Access Manager Compact or Access Manager Terminal Compact
(control unit) in the protected area in order to counteract manipulation and
break-in attempts. The passive reader (for HiSec units) can be used in the
unprotected area. This means that unauthorised persons will have no access
to the Access Manager Compact or Access Manager Terminal Compact
(control unit).
Install the switch box in such a way that the mounting frame can be fitted
straight.
Only the standard configurations are explained in these instructions. The
wiring and the visualisation/signalling of the individual configuration recorded
in the terminal device can be taken from the associated documentation (e. g.
PLC).
You must use special door openers with freewheeling diode for the access
control systems.
Basic instructions for the assembly of the ENiQ Module Reader/Module
Reader Terminal
An ENiQ Module Reader must be connected to a control unit – ENiQ Access
Manager or terminal. The installation of the ENiQ Module Reader depends on
the selected reader variant.
The ENiQ Access Manager/Access Manager Terminal is connected to the
external reader via the RS485 interface with a twisted pair cable for all
variants.
It is not necessary to make any settings on the external reader.
The ENiQ Access Manager/Access Manager Terminal can be supplied
together with the external reader via a power supply unit. Note that a DC
power supply is used.
Make sure that the maximum cable resistance and the maximum cable
length in accordance with the respective technical data sheet are not
exceeded.