Completing the installation of the ENiQ Module Reader or Module
Reader Terminal
93
Completing the installation of the ENiQ Module Reader or Module
Reader Terminal
Tighten the screws of the
terminal(s) to a torque of 50 Ncm.
Fit the connecting terminal(s)
onto the corresponding contact
pins.
ATTENTION!
Functional problems can be caused by connecting terminals
being pinched or pulled off.
Make sure that the connecting terminals are inserted firmly
on the contact pins.
Make sure that cables are placed without tension load in
the surface-mounting frame or switch box.
The installation position of the device is marked by an arrow above the
contact pins. The arrow must point upwards. The devices have DIP
switches. In the installed state, the DIP switches are on the bottom left.
Place the device onto the
installation frame.
Fasten the screws to 100 Ncm
torque.
If necessary you can carefully lift the locking latch of the mounting frame
with a screwdriver to make locking in place more straightforward.