Please note: The installation follows the same steps
as that of the Pro half cylinder as described starting
on page 79. Observe the following information and
follow the installation description starting on page
79. Then execute the functional test described here.
Caution: The figures starting on page 79 show the
installation situation without door handle. When in-
stalling a
Pro cylinder EE
, the installation sequen-
ce also applies for the installation situation with pa-
nic bars according to DIN EN 1125 and and handles
or push pads according to DIN EN 179. The order of
installation remains the same and must be adhered
to under all circumstances. The information must
always be observed. When in doubt, please contact
the manufacturer.
Caution: After each installation, carry out a functio-
nal test. The outside knob must return to its neutral
position on its own after being rotated (cam flush).
A/B:
Turn the outside knob
when engaged a little more
than a fourth of a revoluti-
on in a clockwise or coun-
ter-clockwise direction (11
o‘clock or 1 o‘clock position):
The knob must return to the
neutral position on its own in
both cases (see Fig. C).
If the knob fails to turn back, realign the Pro cylinder
EE and check the lock for any defects.
C:
If you move the outside knob by approximately
one half-turn, the knob will remain in this position
for design reasons (dead centre area).
Caution: After installation, make sure the escape
door lock can be securely unlocked and opened ac-
cording to the specifications of the lock and fittings
manufacturers.
Fig. 35: Functional test
PRO CYLINDER EE WITHOUT
INSIDE KNOB
If you have installed the Pro cylinder properly, you can put the
Pro cylinder into operation.
Caution: In order to put the Pro cylinder in operation
without using the ENiQ® Access Management or ELS
software you only need the Master Card. This is to set
the system‘s identification. This is a one-off process
which must be performed for each reading knob.
Keep the Master Card in a safe place to which only
authorised persons have access. The Master Card
does not have a locking function! If the Master Card
is lost, you must contact your dealer. Extensive repro-
gramming will be required. When the ENiQ® Access
Management or ELS software is used, commissio-
ning can also be carried out without a Master Card.
Please note: Programming with the master and
Programming Card is carried out on each reading
knob. Carry out programming only when the door is
opened so you do not lock yourself out.
Please note: The Pro cylinder automatically detects
transponders upon approaching the reading knob.
In rare cases, environmental factors in the form of
interference fields or the use of transponders not
approved by DOM Sicherheitstechnik may result
in the failure of the DOM ENiQ® cylinder to detect
transponders.
Follow the steps below to initialise the Pro cylinder:
COMMISSIONING