If the permanently open transponder is held in front 
of the terminal device, the terminal device is 
permanently coupled. The colour combination 
shown left appears.

PO: permanently open is activated

(white-green)

PO: permanently open is deactivated

(white-green-red)

When the permanently open transponder is held in 
front of a terminal device that is already in perma-
nently open mode, the terminal device is returned to 
normal operating mode. The colour combination 
shown left appears. 

PO: a transponder is held in front of a device that is already in permanently open mode.

(white-green)

If a terminal device is already in PO mode, the colour 
combination shown left is displayed. The device 
remains in PO mode.

PO: permanently closed transponder is held in front of a device that is already in permanently open 
mode.

(white-green-white-red)

If a terminal device is already in PO mode and a 
permanently closed tag is held in front of the device, 
the colour combination shown left is displayed. The 
device goes into permanently closed mode.

PO: permanently open is deactivated, but remains active by holding a permanently open trans-
ponder in front of the device or triggering the function in the software, e.g. according to a weekly 
schedule

(white-green-red-white-green)

If the permanently open transponder is held
in front of a terminal device that is already in 
permanently open mode by a weekly schedule, the 
terminal device remains in permanently open mode 
and cannot be set to another operating mode. The 
colour combination shown left appears.

6

ELS/ENiQ® signalling

Summary of Contents for ELS signalling

Page 1: ...e small speaker stands for a short beep tone The large speaker stands for a long beep tone Exception PRO only generates a visual signal i Normal operation 2 System 2 Special functions 6 Other 8 Signal...

Page 2: ...ng field of a terminal device and has no authorisation Unauthorised transponder no release red red red After successfully performing an automatic restart the terminal device displays the colour combin...

Page 3: ...LED lights up the door can be opened despite the battery warning level Please replace the batteries When the battery is almost completely empty the terminal indicates this with the signal sequence sho...

Page 4: ...u can now remove the master card from the reading field the device will reset itself and indicate this with the signal sequence shown opposite The device can also be removed via software or app The si...

Page 5: ...d twice green and then immediately remove it from the reading field the 2nd time it lights up green once and yellow once for each additional second Please leave the master card in the reading field fo...

Page 6: ...s displayed The device remains in PO mode PO permanently closed transponder is held in front of a device that is already in permanently open mode white green white red If a terminal device is already...

Page 7: ...ce is returned to normal operating mode The colour combination shown left appears PC a transponder is held in front of a device that is already in permanently closed mode white red If a terminal devic...

Page 8: ...When the RF wake up card is held in front of the device the device lights up blue 6 times Show RF wake up card devices assigned to a system 6x blue If a terminal device is programmed wirelessly and w...

Page 9: ...s being read and written at the ACM ITT the terminal lights up violet Battery change detected yellow green yellow green yellow green yellow When the battery is changed the restart signal is given firs...

Page 10: ...ately until the process is completed 10 With this colour combination the LoQ signals that the Open end position has been reached Open end position reached white green With this colour combination the...

Page 11: ...and by signalling default upper LED only permanent red upper LED only The ACM is in permanently closed mode Stand by signalling permanently closed upper LED only permanent red upper LED only Signallin...

Page 12: ...connection to all terminal devices Stand by signalling RF NetManager no connection to at least one device upper and lower LED permanent Stand by mode of the RF NetManager There is no connection to at...

Page 13: ...No connection can be established to the terminal device Signalling for active connection test of the RF NetManager with poor connection The connection to the terminal device is poor It is recommended...

Page 14: ...device is OK Signalling for active connection test of the RF NetManager with average connectivity Signalling for active connection test of the RF NetManager with good connection The connection betwee...