domat UI90x 

9/2019 Subject to technical changes. 

 

 

UI90x 

Communicative room unit with CO

2

 sensor 

 

 

 

 

 

 

Summary 

The room unit with CO

2

 sensor contains temperature sensor, NDIR CO

2

 sensor for 

carbon  dioxide  concentration  measurement,  optional  humidity  sensor,  and 
control  knob  for  setpoint  control  and  other  settings.  The  binary  output  is 
controlled either on a remote basis, or as thermostat, hygrostat or CO

2

 controller. 

The units communicate over Modbus RTU / RS485 and they can be used as open 
system  components  with  majority  of  building  control  system  and  controllers. 
Compared to the old series UI09x, these types dispose of knob and display blue 
backlight function and more accurate sensors.  
 
All versions of the room units now contain relative humidity measurement. UI092 
and UI094 versions have been replaced. 

 

Beware of unit terminals connection. It differs from its predecessor. 

 

Application 
 

 

Air handling units and air condition in rooms with variable load 

 

schools, cinemas, lecture halls etc. 

 

monitoring and recording of temperature, and CO

2

 concentration 

indoors 

 

Function 
 

The units acquire temperature, CO

2

 concentration, and optionally relative humidity in 

the  room,  temperature  correction  (controlled  by  the  knob)  and  required  operation 
status which is set by short push of the knob or in the menu. In the configurable menu 
following values can be set and displayed: 
 

 

temperature, actual temperature correction 

 

humidity (actual value only at room units containing the humidity sensor) 

 

time (only display at room units with RTC) 

 

basic setpoint - day 

 

basic setpoint - night 

 

outside temperature for heating enable 

Summary of Contents for UI90 Series

Page 1: ...ons of the room units now contain relative humidity measurement UI092 and UI094 versions have been replaced Beware of unit terminals connection It differs from its predecessor Application Air handling units and air condition in rooms with variable load schools cinemas lecture halls etc monitoring and recording of temperature and CO2 concentration indoors Function The units acquire temperature CO2 ...

Page 2: ...e with rolling display of selected values e g actual temperature and CO2 Backlight function Types UI0xxBL dispose of knob and display blue backlight function It is possible to set brightness 0 100 separately for knob and display If user make some action with knob display and knob shine for defined time All of the functions could be set from Modbus master The unit Modbus address and functionality i...

Page 3: ...5 x 30 mm see below Ambient conditions According to class 3K3 5 to 40 C 5 to 85 non condensing relative humidity Storage conditions According to DIN EN 60721 3 1 Climatic class 1K3 5 to 45 C 5 to 95 non condensing relative humidity Standards conformity EMC ed 3 EN 61000 6 2 2005 EN 55022 ed 3 2010 industrial environment Electrical safety EN 60950 1 ed 2 2006 A11 2009 A12 2011 A1 2010 A2 2014 Opr 1...

Page 4: ...N apply power use only the connector without bottom find the controller in the tool Scan set INIT to OFF in the ModComTool tool open the controller window click the Init button in the tool remove and apply power Measuring range The integrated temperature sensor range is 20 to 70 C Read and entered values are available at the RS485 bus where a controller or SCADA reads them The supervising system c...

Page 5: ... one of controllers thermostat hygrostat only at devices with rH sensor controller switching at a predefined CO2 level Setpoint and hysteresis are set over the bus This function is not suitable for standard integrated room control it is to be used as supplementary only The setpoints are not influenced by operation modes Day Night Off Installation Units are intended for operating in a normal and ch...

Page 6: ...with a controller master over RS485 using Modbus RTU and thus they can be used in a number of control and SCADA systems The register description is available in a separate document Room units UI Communication description User manual for domat exe and detailed description of the room unit functions find in the document Room units configuration User manual Display Over Modbus it is possible to set r...

Page 7: ...e with local regulations Safety note The device is designed for monitoring and control of heating ventilation and air conditioning systems It must not be used for protection of persons against health risks or death as a safety element or in applications where its failure could lead to physical or property damage or environmental damage All risks related to device operation must be considered toget...

Page 8: ...2019 Subject to technical changes domat UI90x Changes in versions 01 2017 The first datasheet version 03 2017 Added picture and description of the installation 10 2017 Added Safety note 09 2019 UI907 added ...

Reviews: