Page 13
Door/Window Sensor Advanced User Manual
Compatible Command Classes
Command Class
Notes
Device Reset Locally V1 (5A)
-
Powerlevel V1 (73)
-
Battery V1(80)
-
Association Group Information V1 (59)
-
Z-Wave Plus Info V2 (5E)
Returned Value: 01 06 00 0C 06 0C 06
Z-Wave Plus Version: 01
Role Type: 06
(Slave Sleeping Reporting)
Node Type: 00
(Z-Wave Plus Node)
Installer Icon Type: 0C 06
(Access Control Alarm)
User Icon Type: 0C 06
(Access Control Alarm)
Version V2 (86)
Returned Value: 03 04 21 01 11 1E 00
Z-Wave Library Type: 03
(
Enhanced Slave
)
Protocol Version: 04 21
Protocol Sub-Version: 01 11
Application Version: 1E
Application Sub-Version: 00
Manufacturer Specific V2 (72)
Returned Value: 02 1F 00 03 02 0
1
Manufacturer ID: 02 1F
Product Type: 00 03
Product ID: 02 01
Binary Sensor (30)
If Configuration Parameter 3 is set to 01,
the
Door/Window Sensor
sends a Binary Sensor Report when opened or closed and also when
tamper events are detected. See below for the SENSOR_BINARY_REPORT
parameters sent:
Sensor Type: 0A
(Door/Window)
OPEN Value: FF
CLOSE Value: 00
Sensor Type: 08
(Tamper)
Tamper Detected Value: FF
No Tamper Detected Value: 00
Table 4 - Command Classes
Compatible Command Classes