EN
Installation
EA3280 (A803E)
12
I
The cooling device is designed for free-standing installation, but it can also be
installed in a built-in cabinet. To ensure satisfactory operation and maximum cooling
efficiency the following installation conditions have to be fulfilled:
•
The cooling device must be levelled carefully to ensure proper function.
•
The clearance between the cooling device‘s back and the wall should be 20 mm
or more.
•
Ventilation must be provided as shown in alternatives A, B, C or D (fig.
2
,
page 2).
•
The ventilation duct must at least measure 105 mm x the width of the cooling
device.
•
The entire cooling unit must project into the ventilation duct as shown (fig.
2
,
page 2). Other parts of the device may not project into the ventilation duct.
•
Air passing through the ventilation duct must not be preheated by any source of
heat.
•
Ventilation grills, if used, must have openings of at least 200 cm².
•
The socket outlet for the mains connection must be freely accessible.
6.1
Free-standing installation
To install the cooling device follow these steps:
➤
If needed, change the cooling device‘s feet as shown (fig.
3
, page 2).
➤
Place the cooling device on a firm base.
➤
Connect the connection cable to the AC mains supply.
✓
The cooling device starts cooling the interior.
➤
Set the temperature controller (fig.
1
1, page 2) to the desired temperature
(3 – 12 °C).
NOTE
•
The cooling device should not be exposed to heat radiation from hot
appliances (e.g. stoves).
•
The ventilation apertures at the top of the cooling device must not be
covered up.
Summary of Contents for A 803 E
Page 1: ...EA3280 A803E Fridge Installation and Operating Manual 7 EN REFRIGERATION CLASSIC...
Page 2: ...EA3280 A803E 2 2 1 3 4 1 A D C B 2 1 2 3...
Page 3: ...EA3280 A803E 3 40 mm 10 mm 1 2 4 1 2 mm 6 8 mm 5 6...
Page 4: ...EA3280 A803E 4 1 2 7 8 80 m m 90 9...
Page 5: ...EA3280 A803E 5 2 1 0 2 1 a 8 9 2 4 3 6 7 5 1 b...
Page 6: ...EA3280 A803E 6 180 4 2 1 3 180 c 7 6 5 4 8 9 10 3 1 2 d 2 1 3 e...