background image

8

defrosting process. After defrosting, clean up the defrosted water with a clean

cloth and clean the cooler containers as described in chapter 4.
Should  the  unit  be  out  of  operation  for  a  prolonged  period,  turn  off  unit  and

remove contents. After defrosting, the cooler should be cleaned carefully and

dried.
To  avoid  any  unpleasant  smells  forming  in  the  cooler,  the  lid  should  be  left

slightly open.

15. Measures after prolonged periods of disuse

Should the refrigerator not function correctly after being switched on, place the

unit upside down WITHOUT ANY CONNECTING POWER SUPPLY. After a few

minutes return the refrigerator to its correct position and switch on again.
Should the unit still not fuction correctly, repeat the process several times.

16. Maintenance

Changing the gas filter: the cellulose gas filter is situated at the back in the gas

connection piece. When it becomes necessary to replace the gas filter, remove

the filter from the duct and replace it with a new one. Any other maintenance and

repair  works,  especially  those  relating  to  the  cooling  aggregate  and  the  gas-

burner system, may only be undertaken by authorized customer service points.

17. After-sales service

Should  a  problem  arise  with  the  unit,  please  check  the  following  before

contacting customer service:
- is the unit suitably placed and is it well ventilated?
- is the unit placed on a flat surface?
- does the socket supply current?
- is the connecting cable damaged in any way?
- is there a loose connection?
- has the plug been properly plugged into the socket?
- has the electrothermostat been correctly adjusted?
- in  the  case  of  gas  operation,  has  the  safety  pilot  knob  (regulator)  been

pressed down long enough?

- has the regulating knob been turned to the correct position?
- is the gas cylinder or pressure regulating valve open?
- does the liquid gas cylinder still contain gas? If no liquid movement is evident

on shaking the cylinder, then the gas cylinder is empty.

- are several operating methods being used simultaneously?
- have warm foodstuffs been stored in the cooler?

Summary of Contents for A 803 K

Page 1: ...207 5080 01 0402 A 803 K Operating instructions ...

Page 2: ...2 Fig 1 ...

Page 3: ... Manufacturers food storage recommendations should be strictly adhered to Refer to relevant instructions for food and drink storage under point 13 Under no circumstances should you attempt to repair the appliance yourself Repairs carried out by inexperienced persons may cause injury or more serious malfunctioning This product should be serviced by an authorised Service Engineer and only genuine sp...

Page 4: ...hing up liquid Warning do not inadvertently press or force the opened door past its stop point this could cause the hinges to break Never use scouring or corrosive agents to clean the unit Wipe cleaned surfaces dry with a soft cloth 6 A C operation Do not use any additional form of energy batteries gas Check that the supply voltage and line voltage data correspond to the type plate in the unit WAR...

Page 5: ...er should not be operational when the vehicle is in motion since the battery can discharge to the extent that the vehicle engine cannot restart when the vehicle is at a standstill During transport the door safety button G must remain depressed so that the door is kept in a closed and safe position Recommendation before journey pre cool the unit using A C operation To turn on Plug the car plug must...

Page 6: ...ular care must be taken every time the appliance is connected to the gas bottle to ensure that there are no leaks that the gas pipe rubber hose is not under tension or kinked and that it is not in contact with hot surfaces The connection pipe and gas bottle should always be located in positions where they will not be tripped over or otherwise inadvertently disturbed Before attempting to light the ...

Page 7: ...ient temperature is below 18 C in order to avoid overfreezing the contents 12 Shutting down gas operation Fig 1 2 1 Close gas cylinder or pressure regulating valve 2 Turn knob B clockwise to the off position 13 Food and drink storage Foodstuffs and drinks should always be stored sealed in the unit Thus changes in taste and smell are avoided Food and drink should be so placed in the cooler so as to...

Page 8: ...er remove the filter from the duct and replace it with a new one Any other maintenance and repair works especially those relating to the cooling aggregate and the gas burner system may only be undertaken by authorized customer service points 17 After sales service Should a problem arise with the unit please check the following before contacting customer service is the unit suitably placed and is i...

Page 9: ...n 220 V 240 V mains 50 Hz 130 50 W 12 V 24 V car battery 120 W Capacity 70 l Refrigerant 0 54 kg NH3 H2O The refrigeration cycle has been checked for leaks Depending on the model the controls can be positioned either at the top as depicted or at the bottom no picture Operation is the same in both cases Fig 1 The appliance does not contain any CFCs HCFCs Sodium chromate is used for corrosion protec...

Page 10: ...10 Fig 2 seal ...

Page 11: ...11 ...

Page 12: ...Printed by Xerox Hungary Ltd Rev 2004 02 03 ...

Reviews: