5
removed using a small screwdriver to lever it out. The old fuse should be
replaced by a 3 amp ASTA approved BS 1362 fuse and the fuse cover/carrier
must be refitted before the plug is used again.
If the fuse cover/carrier is lost, a replacement can be obtained from the service
shops. The fuse cover/carrier must be of the same colour as that of the coloured
insert in the base of the plug. In no circumstances must the plug be used without
a correct fuse cover/carrier fitted.
If the plug supplied on the mains lead is not suitable for the socket in your home,
it should be cut off and disposed of safely, or destroyed, to avoid any possible
shock hazard resulting from the plug being inserted into a 13 amp socket
elsewhere in the house. A suitable replacement plug should then be fitted as
given below.
General guide to fitting any plug
Ensure the lengths of wire inside the plug are prepared correctly. Connections
should be firmly made after all conductor strands are entered into the terminal
posts. When preparing the cable ends take care not to damage the outer sheath,
or the insulation surrounding the inner conductors. Tighten all screws. Replace
the top cover of the plug and secure.
Other versions
Your refrigerator has a 3-wire mains lead which is intended for connection to a
3-pin plug and a properly earthed socket outlet.
IMPORTANT:
The wires in the mains lead of this appliance are coloured in
accordance with the following code:
GREEN-AND-YELLOW:
EARTH
BLUE:
NEUTRAL
BROWN:
LIVE
As the colours of the wires in the mains lead may
not correspond with the coloured markings
identifiying the terminals in your plug, proceed
as follows: the wire which is coloured GREEN-
AND-YELLOW must be connected to the
terminal in the plug which is marked with the
letter E or by the earth symbol
or coloured
green or green-and-yellow. The wire which is
coloured BLUE must be connected to the
terminal which is marked with the letter N or coloured black. The wire which is
coloured BROWN must be connected to the terminal which is marked with the
letter L or coloured red.
WARNING - THIS APPLIANCE MUST BE EARTHED!
If a 13 amps (B.S. 1363) fused-plug is used, it should be fitted with a 3 amp fuse.
In other cases, the circuit to which the refrigerator is connected should be fitted
with a 5 amp fuse.
Summary of Contents for A30-100C
Page 1: ...207 5912 05 0402 Type A30 100C Model RF60 Operating instructions GB...
Page 14: ...14 Fig 7 Fig 6 Seal Seals...
Page 15: ......