Replacing the ultraviolet lamp and the nano-mesh divider
Breathe Easy™
26
This is how to replace the ultraviolet lamp and the nano-mesh divider:
➤
Unplug the device from the electrical outlet.
➤
Unscrew the four screws on the corners of the bottom side.
➤
Remove the cover.
➤
Let the device cool down for 5 minutes.
➤
Pull the ultraviolet lamp (fig.
1
3, page 3) out of the lamp socket
(fig.
1
5, page 3).
A
NOTICE!
Do not touch the new ultraviolet lamp with you bare hands as the
oil you leave on it will shorten its service life.
➤
Put the new Dometic ultraviolet lamp into the socket (fig.
1
5, page 3).
Insert the pins on the lamp firmly into the socket.
➤
Place a new maintenance sticker with the current date over the old one
so that you know when the ultraviolet lamp needs to be replaced.
➤
Lift the nano-mesh divider (fig.
1
2, page 3) out of the slots.
➤
Insert the new nano-mesh divider lengthways into the slots.
It does not matter which side faces the ultraviolet lamp.
➤
Clean the device if necessary (see chapter “Cleaning and caring for
Breathe Easy™” on page 27).
➤
Put on the cover.
➤
Fasten the cover with the four screws.
➤
Connect the device to the electrical outlet.
!
WARNING!
Eye damage may result from directly viewing the light produced by
these lamps. To reduce the risk of exposure to UV radiation, take
UV-radiation protective measures for personnel during servicing.
➤
Check that the ultraviolet lamp lights up.
You can see a blue glow through the vents.